Lymphatic Complications in Renal Transplant: Electrosurgical Unit Versus Ultrasonic Cutting and Coagulation Device

Background: Lymphatic complications, particularly lymphocele, are common after renal transplantation and can adversely affect graft function. Electrosurgical units (ESU) and ultrasonic cutting and coagulation devices (UCCD) are widely used, but their comparative effectiveness in preventing lymphatic leakage remains unclear. Methods: A prospective observational comparative study was conducted over two years at Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia (ABVIMS & Dr. RML) Hospital, New Delhi. Statistical analysis was performed using appropriate tests including the Wilcoxon-Mann-Whitney U test, Fisher’s exact test, and Chi-square test; a p-value <0.05 was considered significant. Twenty donor-recipient pairs were included and alternately assigned to either the ESU group (n=10) or the UCCD group (n=10). Outcomes assessed included intraoperative blood loss, postoperative lymphatic complications, urine output, serum creatinine levels, and the need for additional interventions. Results: The incidence of lymphocele was higher in the ESU group (3/10, 30%) compared to the UCCD group (1/10, 10%), though the difference was not statistically significant (p=0.582). Patients in the ESU group required more postoperative imaging (3/10, 30% vs. 1/10, 10%) and interventions (2/10, 20% vs. 0/10, 0%) for lymphatic complications. No significant differences were observed in renal graft function, as measured by serum creatinine reduction and urine output trends. Conclusions: Both surgical techniques resulted in comparable renal function outcomes; however, the UCCD was associated with a lower incidence of lymphatic complications and fewer postoperative interventions. Larger studies are warranted to validate these findings.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-09-25
DOI
https://doi.org/10.5281/zenodo.17350169
Primary Topic
Prenatal Screening and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lymphatic Complications in Renal Transplant: Electrosurgical Unit Versus Ultrasonic Cutting and Coagulation Device

Zenodo (CERN European Organization for Nuclear Research)
Prenatal Screening and Diagnostics
article

Lymphatic Complications in Renal Transplant: Electrosurgical Unit Versus Ultrasonic Cutting and Coagulation Device

article en

Abstract

Background: Lymphatic complications, particularly lymphocele, are common after renal transplantation and can adversely affect graft function. Electrosurgical units (ESU) and ultrasonic cutting and coagulation devices (UCCD) are widely used, but their comparative effectiveness in preventing lymphatic leakage remains unclear. Methods: A prospective observational comparative study was conducted over two years at Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia (ABVIMS & Dr. RML) Hospital, New Delhi. Statistical analysis was performed using appropriate tests including the Wilcoxon-Mann-Whitney U test, Fisher’s exact test, and Chi-square test; a p-value <0.05 was considered significant. Twenty donor-recipient pairs were included and alternately assigned to either the ESU group (n=10) or the UCCD group (n=10). Outcomes assessed included intraoperative blood loss, postoperative lymphatic complications, urine output, serum creatinine levels, and the need for additional interventions. Results: The incidence of lymphocele was higher in the ESU group (3/10, 30%) compared to the UCCD group (1/10, 10%), though the difference was not statistically significant (p=0.582). Patients in the ESU group required more postoperative imaging (3/10, 30% vs. 1/10, 10%) and interventions (2/10, 20% vs. 0/10, 0%) for lymphatic complications. No significant differences were observed in renal graft function, as measured by serum creatinine reduction and urine output trends. Conclusions: Both surgical techniques resulted in comparable renal function outcomes; however, the UCCD was associated with a lower incidence of lymphatic complications and fewer postoperative interventions. Larger studies are warranted to validate these findings.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 28%
Prenatal Screening and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lymphatic Complications in Renal Transplant: Electrosurgical Unit Versus Ultrasonic Cutting and Coagulation Device · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS