Mechanical vibration study of low-energy superconducting linear accelerator (SCL3) in RAON

Recently, the Institute for Rare Isotope Science (IRIS, previously RISP) in the Institute for Basic Science (IBS), Daejeon, South Korea, finished the first beam commissioning for operating of low-energy superconducting linear accelerator (SCL3). SCL3 is composed of two types of cavity, quarter wave resonator (QWR) which has 81.25 MHz RF frequency and half wave resonator (HWR) which has 162.5 MHz RF frequency. During operation, RF control was very complicated due to many issues including mechanical vibrations coming from vacuum pump, cryogenic valve, or undefined source. In this paper, we will discuss the SCL3 mechanical vibration data measured by a laser doppler vibrometer (LDV). In addition, the mechanical vibration of SCL3 cryogenic components such as transfer lines and supports will be also described.

Publication Details

Journal
JACOW
Published
2025-10-14
DOI
https://doi.org/10.18429/jacow-hiat2025-mop14
Primary Topic
Preterm Birth and Chorioamnionitis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical vibration study of low-energy superconducting linear accelerator (SCL3) in RAON

JACOW
Preterm Birth and Chorioamnionitis
article

Mechanical vibration study of low-energy superconducting linear accelerator (SCL3) in RAON

article en

Abstract

Recently, the Institute for Rare Isotope Science (IRIS, previously RISP) in the Institute for Basic Science (IBS), Daejeon, South Korea, finished the first beam commissioning for operating of low-energy superconducting linear accelerator (SCL3). SCL3 is composed of two types of cavity, quarter wave resonator (QWR) which has 81.25 MHz RF frequency and half wave resonator (HWR) which has 162.5 MHz RF frequency. During operation, RF control was very complicated due to many issues including mechanical vibrations coming from vacuum pump, cryogenic valve, or undefined source. In this paper, we will discuss the SCL3 mechanical vibration data measured by a laser doppler vibrometer (LDV). In addition, the mechanical vibration of SCL3 cryogenic components such as transfer lines and supports will be also described.

JACOW
Affordable and clean energy
Openalex Percentile: Top 37%
Preterm Birth and Chorioamnionitis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.