Design of a Capacitive Level Sensor for Nitroglycerin Synthesis

The synthesis of nitroglycerin requires extremely precise control of reactant volumes due to its highly sensitive and hazardous nature. This study evaluates the performance of a capacitive level sensor integrated with a Fuzzy-PID controller capable of adapting to error dynamics while utilizing an ESP32 microcontroller and a peristaltic pump. The sensor was tested for accuracy, precision, linearity, resolution, response time, hysteresis, stability, and sensitivity. The results demonstrated an accuracy of 99.4%, an R² value of 0.997, a resolution of 0.1 mL, and a response time of 4.98 seconds. The system exhibited high precision and stable performance, offering a potential solution for enhancing the reliability and safety of nitroglycerin production.

Institutions

Publication Details

Journal
Jurnal EECCIS (Electrics Electronics Communications Controls Informatics Systems)
Published
2025-08-30
DOI
https://doi.org/10.21776/jeeccis.v19i2.1822
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a Capacitive Level Sensor for Nitroglycerin Synthesis

Jurnal EECCIS (Electrics Electronics Communications Controls Informatics Systems)
Electrochemical sensors and biosensors
article

Design of a Capacitive Level Sensor for Nitroglycerin Synthesis

article en

Abstract

The synthesis of nitroglycerin requires extremely precise control of reactant volumes due to its highly sensitive and hazardous nature. This study evaluates the performance of a capacitive level sensor integrated with a Fuzzy-PID controller capable of adapting to error dynamics while utilizing an ESP32 microcontroller and a peristaltic pump. The sensor was tested for accuracy, precision, linearity, resolution, response time, hysteresis, stability, and sensitivity. The results demonstrated an accuracy of 99.4%, an R² value of 0.997, a resolution of 0.1 mL, and a response time of 4.98 seconds. The system exhibited high precision and stable performance, offering a potential solution for enhancing the reliability and safety of nitroglycerin production.

Jurnal EECCIS (Electrics Electronics Communications Controls Informatics Systems)Vol. 19(2)
California Polytechnic State University (US), University of Brawijaya (ID)
Affordable and clean energy
Openalex Percentile: Top 49%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.