Optimal Location and Sizing of Static Var Compensator ( <scp>SVC</scp> ) to Improve Voltage Profile in Distribution Network

ABSTRACT Insufficient reactive power in electrical power systems leads to voltage instability, limiting the ability to deliver power to loads and adversely affecting overall system reliability. This study employs the IEEE 33‐bus system to investigate the effectiveness of a Static Var Compensator (SVC) in enhancing a distribution network's voltage profile. The system was modeled and simulated in the Electrical Transient Analyzer Program (ETAP), both with and without SVC integration. An Optimal Capacitor Placement (OCP) strategy was used to establish the optimal location and sizing for the SVC, ensuring that bus voltages are kept within the permitted operational limit of 0.950–1.050 p.u. Power flow analysis was performed using the Newton–Raphson method to investigate the network's voltage performance in both scenarios. The results indicate that the average bus voltage improved from 94.69% without compensation to 97.90% with SVC installation. The optimally placed SVC, rated at ±3.6 Mvar (3.6 Mvar capacitive and 3.6 Mvar inductive), effectively stabilized the system and improved voltage quality. These findings confirm that SVC integration is a viable and efficient solution for enhancing voltage stability in distribution networks.

Institutions

Publication Details

Journal
Engineering Reports
Published
2025-10-01
DOI
https://doi.org/10.1002/eng2.70435
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Location and Sizing of Static Var Compensator ( SVC ) to Improve Voltage Profile in Distribution Network

Engineering Reports
Power System Optimization and Stability
article

Optimal Location and Sizing of Static Var Compensator ( SVC ) to Improve Voltage Profile in Distribution Network

article en

Abstract

ABSTRACT Insufficient reactive power in electrical power systems leads to voltage instability, limiting the ability to deliver power to loads and adversely affecting overall system reliability. This study employs the IEEE 33‐bus system to investigate the effectiveness of a Static Var Compensator (SVC) in enhancing a distribution network's voltage profile. The system was modeled and simulated in the Electrical Transient Analyzer Program (ETAP), both with and without SVC integration. An Optimal Capacitor Placement (OCP) strategy was used to establish the optimal location and sizing for the SVC, ensuring that bus voltages are kept within the permitted operational limit of 0.950–1.050 p.u. Power flow analysis was performed using the Newton–Raphson method to investigate the network's voltage performance in both scenarios. The results indicate that the average bus voltage improved from 94.69% without compensation to 97.90% with SVC installation. The optimally placed SVC, rated at ±3.6 Mvar (3.6 Mvar capacitive and 3.6 Mvar inductive), effectively stabilized the system and improved voltage quality. These findings confirm that SVC integration is a viable and efficient solution for enhancing voltage stability in distribution networks.

Engineering ReportsVol. 7(10)
Debre Tabor University (ET)
Affordable and clean energy
Openalex Percentile: Top 49%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimal Location and Sizing of Static Var Compensator ( <scp>SVC</scp> ) to Improve Voltage Profile in Distribution Network · Engineering Reports (2025) | TGRS Research Map | TGRS