Dynamic modelling and control of a Small Modular Reactor in load following by cogeneration mode

The growing penetration of variable renewable sources is shifting the operational paradigm of nuclear power plants, traditionally operated as baseload generators, with flexible operation becoming fundamental not only to complement the non-programmability of renewables but also to ensure economic competitiveness. This study aims at evaluating the flexible operation capabilities of a soluble-boron-free, pressurised water type Small Modular Reactor (SMR). The traditional load following capability of the power plant, adopting a reactor-follows-turbine strategy, is compared to the load following by cogeneration mode. For the latter, two steam extraction points were considered to deliver excess thermal power to a generic non-electric application. The load following capabilities are assessed by means of a dynamic simulator of the nuclear power plant, developed in the object-oriented modelling language Modelica within the Dymola simulation environment. Specifically, the dynamic models of the SMR and the power conversion system are used to test the system’s response to variable load demands. Moreover, a control strategy based on a decentralised feedback approach, with control and process variables paired with the support of the relative gain array technique, is proposed to meet grid requirements. Results demonstrate that both traditional and load following by cogeneration can effectively meet variable demands using the proposed control strategy. Cogeneration mode improves cycle efficiency by using the extracted heat as a valuable output while keeping the reactor at rated conditions. In particular, a higher efficiency is achieved when extracting low-temperature steam, with a power loss factor of 0.32 compared to 0.46 for high-temperature extraction. The transient simulation confirms that load following by cogeneration can meet grid requirements by limiting frequency deviations to less than 40 mHz, compared to the 60 mHz in conventional load following, without the need to modulate the core power through external reactivity insertions. In conclusion, the findings of this study suggest that load following by cogeneration could be a viable solution to meet the increasing flexibility requirements while reducing solicitations to the reactor’s primary loop. The proposed dynamic model could be extended to simulate the response of a comprehensive nuclear hybrid energy system, including the dynamics of the coupled cogeneration systems, to explore the overall system’s response in different scenarios. • Investigation of the load following by cogeneration operational mode. • Development of a dynamic simulator of a SMR and its balance of plant in Modelica. • Comparison between conventional load following and load following by cogeneration. • Decentralised control strategy defined using the relative gain array technique. • Grid requirements can be met by flexibly allocating power to a cogeneration system.

Institutions

Publication Details

Journal
Nuclear Engineering and Design
Published
2025-10-13
DOI
https://doi.org/10.1016/j.nucengdes.2025.114518
Citations
1
Primary Topic
Modeling and Simulation Systems
Type
article
Field-Weighted Citation Impact
1.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic modelling and control of a Small Modular Reactor in load following by cogeneration mode

1 citations
Nuclear Engineering and Design
Modeling and Simulation Systems
1.50
article

Dynamic modelling and control of a Small Modular Reactor in load following by cogeneration mode

article en
1 citations

Abstract

The growing penetration of variable renewable sources is shifting the operational paradigm of nuclear power plants, traditionally operated as baseload generators, with flexible operation becoming fundamental not only to complement the non-programmability of renewables but also to ensure economic competitiveness. This study aims at evaluating the flexible operation capabilities of a soluble-boron-free, pressurised water type Small Modular Reactor (SMR). The traditional load following capability of the power plant, adopting a reactor-follows-turbine strategy, is compared to the load following by cogeneration mode. For the latter, two steam extraction points were considered to deliver excess thermal power to a generic non-electric application. The load following capabilities are assessed by means of a dynamic simulator of the nuclear power plant, developed in the object-oriented modelling language Modelica within the Dymola simulation environment. Specifically, the dynamic models of the SMR and the power conversion system are used to test the system’s response to variable load demands. Moreover, a control strategy based on a decentralised feedback approach, with control and process variables paired with the support of the relative gain array technique, is proposed to meet grid requirements. Results demonstrate that both traditional and load following by cogeneration can effectively meet variable demands using the proposed control strategy. Cogeneration mode improves cycle efficiency by using the extracted heat as a valuable output while keeping the reactor at rated conditions. In particular, a higher efficiency is achieved when extracting low-temperature steam, with a power loss factor of 0.32 compared to 0.46 for high-temperature extraction. The transient simulation confirms that load following by cogeneration can meet grid requirements by limiting frequency deviations to less than 40 mHz, compared to the 60 mHz in conventional load following, without the need to modulate the core power through external reactivity insertions. In conclusion, the findings of this study suggest that load following by cogeneration could be a viable solution to meet the increasing flexibility requirements while reducing solicitations to the reactor’s primary loop. The proposed dynamic model could be extended to simulate the response of a comprehensive nuclear hybrid energy system, including the dynamics of the coupled cogeneration systems, to explore the overall system’s response in different scenarios. • Investigation of the load following by cogeneration operational mode. • Development of a dynamic simulator of a SMR and its balance of plant in Modelica. • Comparison between conventional load following and load following by cogeneration. • Decentralised control strategy defined using the relative gain array technique. • Grid requirements can be met by flexibly allocating power to a cogeneration system.

Nuclear Engineering and DesignVol. 445
Politecnico di Milano (IT)
Affordable and clean energy
Openalex Percentile: Top 11%
Modeling and Simulation Systems
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.