Analysis and Simulation of Load Unbalance of Distribution Transformer Feeder Lk.10 in ULP Medan City

Load imbalance in three-phase distribution transformers leads to high neutral currents, increased power losses, and decreased system efficiency. This study aims to analyze and simulate load imbalances on distribution transformers located on Feeder LK.10 at PT PLN (Persero) ULP Medan Kota. Data collection was conducted through field measurements of voltage and current, followed by manual calculations and simulations using ETAP 19. The analysis focused on load imbalance percentage, transformer loading, neutral current, and power losses. Results indicate that several transformers exhibit critical imbalance conditions, with some exceeding 25% load imbalance and significant neutral current. The ETAP 19 simulation results show a high level of accuracy compared to actual field measurements, with an average error below 3%. This study confirms that accurate monitoring and proper load redistribution are essential to maintain distribution transformer performance. The findings are expected to support PLN in improving power quality and reliability in distribution systems.

Institutions

Publication Details

Journal
Holistic Science
Published
2025-08-14
DOI
https://doi.org/10.56495/hs.v5i2.1239
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Simulation of Load Unbalance of Distribution Transformer Feeder Lk.10 in ULP Medan City

Holistic Science
Power Quality and Harmonics
article

Analysis and Simulation of Load Unbalance of Distribution Transformer Feeder Lk.10 in ULP Medan City

article en

Abstract

Load imbalance in three-phase distribution transformers leads to high neutral currents, increased power losses, and decreased system efficiency. This study aims to analyze and simulate load imbalances on distribution transformers located on Feeder LK.10 at PT PLN (Persero) ULP Medan Kota. Data collection was conducted through field measurements of voltage and current, followed by manual calculations and simulations using ETAP 19. The analysis focused on load imbalance percentage, transformer loading, neutral current, and power losses. Results indicate that several transformers exhibit critical imbalance conditions, with some exceeding 25% load imbalance and significant neutral current. The ETAP 19 simulation results show a high level of accuracy compared to actual field measurements, with an average error below 3%. This study confirms that accurate monitoring and proper load redistribution are essential to maintain distribution transformer performance. The findings are expected to support PLN in improving power quality and reliability in distribution systems.

Holistic ScienceVol. 5(2)
Universitas Pembangunan Panca Budi Medan (ID)
Affordable and clean energy
Openalex Percentile: Top 49%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.