Combination of an OMEGATM LAA-occluder with the Amplatzer AmuletTM Delivery Sheath for Complex LAA Device Closure

Introduction: HInterventional Left Atrial Appendage Occlusion (LAAO) has been established as an alternative to Oral Anticoagulation (OAC) in patients with Atrial Fibrillation (Afib) at high stroke risk and competing bleeding risk factors.The complexity of LAAO procedures depend on the anatomy of the LAA itself, its relation to the surrounding anatomical structures, and device specific properties.We present the case of a 90-year-old male, who was referred to our center for LAAO.The anatomy of the LAA was suitable for the use of a lobe-disc OMEGA-Device.However, coaxial placement of the occluder was not possible with the pre-shaped device sheath.After several unsuccessful attempts we adapted our interventional strategy by combining the unique features of the OMEGA-Device with the favourable characteristics of a 14Fr-double curve Amulet-Delivery-Sheath.This finally allowed for an optimal positioning of the 18mm-OMEGA-Device in the preselected landing zone with the intended perfect sealing of the LAA ostium.This case nicely demonstrates potentially important interdependency of structural cardiac interventions with device specific characteristics.

Publication Details

Journal
Open Journal of Cardiology & Heart Diseases
Published
2025-01-22
DOI
https://doi.org/10.31031/ojchd.2025.04.000594
Primary Topic
Surgical site infection prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combination of an OMEGATM LAA-occluder with the Amplatzer AmuletTM Delivery Sheath for Complex LAA Device Closure

Open Journal of Cardiology & Heart Diseases
Surgical site infection prevention
article

Combination of an OMEGATM LAA-occluder with the Amplatzer AmuletTM Delivery Sheath for Complex LAA Device Closure

article en

Abstract

Introduction: HInterventional Left Atrial Appendage Occlusion (LAAO) has been established as an alternative to Oral Anticoagulation (OAC) in patients with Atrial Fibrillation (Afib) at high stroke risk and competing bleeding risk factors.The complexity of LAAO procedures depend on the anatomy of the LAA itself, its relation to the surrounding anatomical structures, and device specific properties.We present the case of a 90-year-old male, who was referred to our center for LAAO.The anatomy of the LAA was suitable for the use of a lobe-disc OMEGA-Device.However, coaxial placement of the occluder was not possible with the pre-shaped device sheath.After several unsuccessful attempts we adapted our interventional strategy by combining the unique features of the OMEGA-Device with the favourable characteristics of a 14Fr-double curve Amulet-Delivery-Sheath.This finally allowed for an optimal positioning of the 18mm-OMEGA-Device in the preselected landing zone with the intended perfect sealing of the LAA ostium.This case nicely demonstrates potentially important interdependency of structural cardiac interventions with device specific characteristics.

Open Journal of Cardiology & Heart DiseasesVol. 4(4)
Openalex Percentile: Top 33%
Surgical site infection prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Combination of an OMEGATM LAA-occluder with the Amplatzer AmuletTM Delivery Sheath for Complex LAA Device Closure · Open Journal of Cardiology & Heart Diseases (2025) | TGRS Research Map | TGRS