METHOD DEVELOPMENT AND VALIDATION OF VALSARTAN BY RP-HPLC

A simple, precise, accurate, and environmentally friendly RP-HPLC method was developed and validated for the determination of Valsartan in bulk and pharmaceutical formulations. Chromatographic separation was achieved using an Inertsil ODS C8 (100 × 4.6 mm, 5 µm) column with a mobile phase consisting of acetonitrile and potassium dihydrogen phosphate buffer (pH 6.1) in a 30:70 v/v ratio. The flow rate was maintained at 1.5 mL/min, detection was carried out at 247 nm, and the column temperature was kept at 27 °C. The retention time of Valsartan was found to be 4.705 min. The method showed excellent linearity (25–125 µg/mL) with a correlation coefficient of 0.9999, precision with %RSD below 0.5%, and recovery of 99.69%. The LOD and LOQ values were 1.468 µg/mL and 4.45 µg/mL, respectively. The method was validated as per ICH guidelines and successfully applied to commercial tablet dosage forms, proving its suitability for routine quality control analysis. KEY WORDS: Method development, RP-HPLC, Valsartan, Method validation.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-12
DOI
https://doi.org/10.5281/zenodo.17333945
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

METHOD DEVELOPMENT AND VALIDATION OF VALSARTAN BY RP-HPLC

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

METHOD DEVELOPMENT AND VALIDATION OF VALSARTAN BY RP-HPLC

article en

Abstract

A simple, precise, accurate, and environmentally friendly RP-HPLC method was developed and validated for the determination of Valsartan in bulk and pharmaceutical formulations. Chromatographic separation was achieved using an Inertsil ODS C8 (100 × 4.6 mm, 5 µm) column with a mobile phase consisting of acetonitrile and potassium dihydrogen phosphate buffer (pH 6.1) in a 30:70 v/v ratio. The flow rate was maintained at 1.5 mL/min, detection was carried out at 247 nm, and the column temperature was kept at 27 °C. The retention time of Valsartan was found to be 4.705 min. The method showed excellent linearity (25–125 µg/mL) with a correlation coefficient of 0.9999, precision with %RSD below 0.5%, and recovery of 99.69%. The LOD and LOQ values were 1.468 µg/mL and 4.45 µg/mL, respectively. The method was validated as per ICH guidelines and successfully applied to commercial tablet dosage forms, proving its suitability for routine quality control analysis. KEY WORDS: Method development, RP-HPLC, Valsartan, Method validation.

Zenodo (CERN European Organization for Nuclear Research)
Life in Land
Openalex Percentile: Top 49%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.