An Android-Based Embedded Modified Iterative Fusion Deep Neural Network for Automated Detection of Macular Diseases Using OCT Images

Retinal optical coherence tomography (OCT) is a noninvasive and high-resolution diagnostic imaging modality used for early detection of choroidal neovascularization (CNV), diabetic macular edema (DME), and drusen-based macular diseases (MDs). The manual procedure for screening these MDs using OCT images is cumbersome and may result in a false diagnosis. Hence, there is a requirement for an artificial intelligence-enabled automated approach for the accurate detection of macular disorders. This paper presents a modified iterative fusion deep neural network (MIFDNN) model and its implementation on an Android framework for the automated detection of CNV, DME, and drusen using OCT images. Initially, the U-Net model is used to obtain the enhanced OCT image from the noisy OCT image. The enhanced OCT image is used as input for the proposed MIFDNN model for detecting MDs. The MIFDNN employs a sophisticated dual-branch architecture comprising a custom basic branch deep convolutional neural network (CNN) module for hierarchical feature extraction, a fusion branch for iterative multiscale feature integration, dense layers, and a softmax layer for detecting MDs. The basic branch deep CNN consists of five convolution layers, five batch normalization (BN) layers, and three max-pooling layers. The classification performance of the proposed MIFDNN model is evaluated using OCT images from a public dataset. Our model has achieved a remarkable average classification accuracy of 98.17% using a 3-fold cross-validation strategy, outperforming several existing methods to detect MDs using OCT images. To facilitate real-world application, we have performed post-training quantization to reduce the size of the proposed MIFDNN model. The quantized model is successfully deployed on an Android platform, where the on-device inference maintained an impressive 98% accuracy with a throughput of approximately 92 images per minute, validating the proposed model’s practical feasibility for screening MDs using OCT images. Received: 11 July 2025 | Revised: 9 September 2025 | Accepted: 23 September 2025 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement The data that support the findings of this study are openly available in [Mendeley, Kaggle] at [https://data.mendeley.com/datasets/rscbjbr9sj/3, https://www.kaggle.com/datasets/obulisainaren/retinal-oct-c8]. Author Contribution Statement Umar Shafiq Ahmad: Methodology, Software, Validation, Formal analysis, Investigation, Resources, Data curation, Writing – original draft. Rajesh Kumar Tripathy: Conceptualization, Writing – review & editing, Visualization, Supervision, Project administration.

Institutions

Publication Details

Journal
Smart Wearable Technology
Published
2025-10-13
DOI
https://doi.org/10.47852/bonviewswt52026773
Primary Topic
Liver physiology and pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Android-Based Embedded Modified Iterative Fusion Deep Neural Network for Automated Detection of Macular Diseases Using OCT Images

Smart Wearable Technology
Liver physiology and pathology
article

An Android-Based Embedded Modified Iterative Fusion Deep Neural Network for Automated Detection of Macular Diseases Using OCT Images

article en

Abstract

Retinal optical coherence tomography (OCT) is a noninvasive and high-resolution diagnostic imaging modality used for early detection of choroidal neovascularization (CNV), diabetic macular edema (DME), and drusen-based macular diseases (MDs). The manual procedure for screening these MDs using OCT images is cumbersome and may result in a false diagnosis. Hence, there is a requirement for an artificial intelligence-enabled automated approach for the accurate detection of macular disorders. This paper presents a modified iterative fusion deep neural network (MIFDNN) model and its implementation on an Android framework for the automated detection of CNV, DME, and drusen using OCT images. Initially, the U-Net model is used to obtain the enhanced OCT image from the noisy OCT image. The enhanced OCT image is used as input for the proposed MIFDNN model for detecting MDs. The MIFDNN employs a sophisticated dual-branch architecture comprising a custom basic branch deep convolutional neural network (CNN) module for hierarchical feature extraction, a fusion branch for iterative multiscale feature integration, dense layers, and a softmax layer for detecting MDs. The basic branch deep CNN consists of five convolution layers, five batch normalization (BN) layers, and three max-pooling layers. The classification performance of the proposed MIFDNN model is evaluated using OCT images from a public dataset. Our model has achieved a remarkable average classification accuracy of 98.17% using a 3-fold cross-validation strategy, outperforming several existing methods to detect MDs using OCT images. To facilitate real-world application, we have performed post-training quantization to reduce the size of the proposed MIFDNN model. The quantized model is successfully deployed on an Android platform, where the on-device inference maintained an impressive 98% accuracy with a throughput of approximately 92 images per minute, validating the proposed model’s practical feasibility for screening MDs using OCT images. Received: 11 July 2025 | Revised: 9 September 2025 | Accepted: 23 September 2025 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement The data that support the findings of this study are openly available in [Mendeley, Kaggle] at [https://data.mendeley.com/datasets/rscbjbr9sj/3, https://www.kaggle.com/datasets/obulisainaren/retinal-oct-c8]. Author Contribution Statement Umar Shafiq Ahmad: Methodology, Software, Validation, Formal analysis, Investigation, Resources, Data curation, Writing – original draft. Rajesh Kumar Tripathy: Conceptualization, Writing – review & editing, Visualization, Supervision, Project administration.

Smart Wearable Technology
Birla Institute of Technology, Mesra (IN), Birla Institute of Technology and Science, Pilani (IN)
Openalex Percentile: Top 37%
Liver physiology and pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.