BULLET: Lead corrosion and erosion test facility

• A newly commissioned lead-loop facility designed for materials testing is presented. • BULLET has an oxygen control system and can reach a maximum lead velocity up to 6 m/s. • Preliminary test results on 316H and aluminised 316H samples are provided. We present the BULLET (Bangor University Lead Loop Erosion/corrosion Test) facility which was designed and built for erosion and corrosion testing of materials in flowing and stagnant lead at temperatures, with the unique capability to reach very high lead velocities when operated in flowing conditions. In general, the aim of the facility is to carry out frontier research on erosion/corrosion effects on materials, components, and instrumentation, and on the thermal hydraulics of lead circulation loop. The facility is provided with an oxygen control system and can operate at up to 480 °C in the flow loop, in which lead velocities up to 6 m/s can be achieved, and at up to 600 °C in the stagnant test capsule. In addition to describing the facility, we also present preliminary erosion/corrosion test results on uncoated and aluminised 316H samples, collected during an initial commissioning phase of the BULLET facility. The samples were exposed for 500 h to flowing lead with a velocity of 3.3 m/s and an oxygen level of 10 −8 wt% at 420 °C. The samples were characterized using Optical- and Scanning electron microscopy, Energy dispersive X-ray spectroscopy and X-ray diffraction. Preliminary observations are provided while further confirmatory tests are ongoing.

Institutions

Publication Details

Journal
Nuclear Engineering and Design
Published
2025-10-13
DOI
https://doi.org/10.1016/j.nucengdes.2025.114535
Citations
1
Primary Topic
Nuclear Engineering Thermal-Hydraulics
Type
article
Field-Weighted Citation Impact
4.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BULLET: Lead corrosion and erosion test facility

1 citations
Nuclear Engineering and Design
Nuclear Engineering Thermal-Hydraulics
4.99
article

BULLET: Lead corrosion and erosion test facility

article en
1 citations

Abstract

• A newly commissioned lead-loop facility designed for materials testing is presented. • BULLET has an oxygen control system and can reach a maximum lead velocity up to 6 m/s. • Preliminary test results on 316H and aluminised 316H samples are provided. We present the BULLET (Bangor University Lead Loop Erosion/corrosion Test) facility which was designed and built for erosion and corrosion testing of materials in flowing and stagnant lead at temperatures, with the unique capability to reach very high lead velocities when operated in flowing conditions. In general, the aim of the facility is to carry out frontier research on erosion/corrosion effects on materials, components, and instrumentation, and on the thermal hydraulics of lead circulation loop. The facility is provided with an oxygen control system and can operate at up to 480 °C in the flow loop, in which lead velocities up to 6 m/s can be achieved, and at up to 600 °C in the stagnant test capsule. In addition to describing the facility, we also present preliminary erosion/corrosion test results on uncoated and aluminised 316H samples, collected during an initial commissioning phase of the BULLET facility. The samples were exposed for 500 h to flowing lead with a velocity of 3.3 m/s and an oxygen level of 10 −8 wt% at 420 °C. The samples were characterized using Optical- and Scanning electron microscopy, Energy dispersive X-ray spectroscopy and X-ray diffraction. Preliminary observations are provided while further confirmatory tests are ongoing.

Nuclear Engineering and DesignVol. 445
Bangor University (GB), National Nuclear Laboratory (GB), Centro Interuniversitario di Ricerca Per lo Sviluppo sostenibile (IT), Westinghouse Electric (United States) (US)
Openalex Percentile: Top 4%
Nuclear Engineering Thermal-Hydraulics
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

BULLET: Lead corrosion and erosion test facility · Nuclear Engineering and Design (2025) | TGRS Research Map | TGRS