Enhancing the Efficiency of the Turbogenerator Cooling System Through the Use of Finned Tubes in the Gas Cooler

The reliability of a high-power turbogenerator largely depends on its cooling system. The trouble-free and efficient operation of this system, in particular the gas cooler, is a problem that has not been fully resolved as of now. A modernized design of a gas cooler for a 325 MW turbogenerator, featuring high-finned bimetallic tubes, is proposed in the paper. To substantiate the efficiency of such a design and determine the heat transfer reserve of the gas cooler, its thermal state was calculated. The obtained results showed that the water overheating in the gas cooler is 5 °C. At the same time, one section of the gas cooler provides heat loss removal of 1266 kW at a hydrogen flow rate of 6.66 m3/s and a cooling water flow rate of 200 m3/s, which meets the requirements for this gas cooler.

Publication Details

Journal
Journal of Mechanical Engineering
Published
2025-09-30
DOI
https://doi.org/10.15407/pmach2025.03.034
Primary Topic
Biofuel production and bioconversion
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the Efficiency of the Turbogenerator Cooling System Through the Use of Finned Tubes in the Gas Cooler

Journal of Mechanical Engineering
Biofuel production and bioconversion
article

Enhancing the Efficiency of the Turbogenerator Cooling System Through the Use of Finned Tubes in the Gas Cooler

article en

Abstract

The reliability of a high-power turbogenerator largely depends on its cooling system. The trouble-free and efficient operation of this system, in particular the gas cooler, is a problem that has not been fully resolved as of now. A modernized design of a gas cooler for a 325 MW turbogenerator, featuring high-finned bimetallic tubes, is proposed in the paper. To substantiate the efficiency of such a design and determine the heat transfer reserve of the gas cooler, its thermal state was calculated. The obtained results showed that the water overheating in the gas cooler is 5 °C. At the same time, one section of the gas cooler provides heat loss removal of 1266 kW at a hydrogen flow rate of 6.66 m3/s and a cooling water flow rate of 200 m3/s, which meets the requirements for this gas cooler.

Journal of Mechanical EngineeringVol. 28(3)
Affordable and clean energy
Openalex Percentile: Top 51%
Biofuel production and bioconversion
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.