Analysis of Harmonics in Goma Power Distribution System

Non-linear load is the major element in a network to rise harmonics due to its characteristics. Harmonics are creating a lot of problems and disturbing the electrical network such as malfunction of electrical devices, efficiency reduction as well as reduction of the effective lifetime of electrical devices. This paper proposes a study of harmonics and analysis of filter to be implemented in order to remove higher-order harmonics and total harmonic distortion of current in the electric power systems of Goma that can be a key for proper connection to a smart grid for any network and to move to it in Goma network. Simulation results in Matlab/Simulink are presented and compared for the distorted IEEE-519 - 15kV without filtering and with a passive filter as well as an active filter.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-12
DOI
https://doi.org/10.5281/zenodo.17335499
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Harmonics in Goma Power Distribution System

Zenodo (CERN European Organization for Nuclear Research)
Power Quality and Harmonics
article

Analysis of Harmonics in Goma Power Distribution System

article en

Abstract

Non-linear load is the major element in a network to rise harmonics due to its characteristics. Harmonics are creating a lot of problems and disturbing the electrical network such as malfunction of electrical devices, efficiency reduction as well as reduction of the effective lifetime of electrical devices. This paper proposes a study of harmonics and analysis of filter to be implemented in order to remove higher-order harmonics and total harmonic distortion of current in the electric power systems of Goma that can be a key for proper connection to a smart grid for any network and to move to it in Goma network. Simulation results in Matlab/Simulink are presented and compared for the distorted IEEE-519 - 15kV without filtering and with a passive filter as well as an active filter.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 49%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.