Stability Indicating Method Development and Validation of Polmacoxib in Bulk and Capsule Dosage Form by Rp-Hplc Method

A Simple, rapid, economical, precise and accurate Stability indicating RP- HPLC method for the estimation of Polmacoxib has been developed. A reverse phase high performance liquid chromatographic method was developed for the estimation of Polmacoxib has been developed. The separation was achieved Column Shimadzu C18 (4.6 x 250 mm, 5µm), isocratic program Acetonitrile: Methanol: Water (40:40:20 % v/v/v) as a mobile phase, at the flow rate of 1 ml/min. Detection was carried out at 316 nm and the retention time of Polmacoxib was found to be 3.658 min. The method has been validated for linearity, accuracy, precision, robustness, ruggedness. Linearity observed for Polmacoxib 12-60 μg/ml. Developed method was found to be accurate, precise and rapid and time consuming for estimation of Polmacoxib and the drug was subjected to stress condition of acidic, basic, oxidation, reduction, UV light degradation, under same chromatographic condition. The stress samples were assayed on RP-HPLC system.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-12
DOI
https://doi.org/10.5281/zenodo.17334320
Primary Topic
Lattice Boltzmann Simulation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability Indicating Method Development and Validation of Polmacoxib in Bulk and Capsule Dosage Form by Rp-Hplc Method

Zenodo (CERN European Organization for Nuclear Research)
Lattice Boltzmann Simulation Studies
article

Stability Indicating Method Development and Validation of Polmacoxib in Bulk and Capsule Dosage Form by Rp-Hplc Method

article en

Abstract

A Simple, rapid, economical, precise and accurate Stability indicating RP- HPLC method for the estimation of Polmacoxib has been developed. A reverse phase high performance liquid chromatographic method was developed for the estimation of Polmacoxib has been developed. The separation was achieved Column Shimadzu C18 (4.6 x 250 mm, 5µm), isocratic program Acetonitrile: Methanol: Water (40:40:20 % v/v/v) as a mobile phase, at the flow rate of 1 ml/min. Detection was carried out at 316 nm and the retention time of Polmacoxib was found to be 3.658 min. The method has been validated for linearity, accuracy, precision, robustness, ruggedness. Linearity observed for Polmacoxib 12-60 μg/ml. Developed method was found to be accurate, precise and rapid and time consuming for estimation of Polmacoxib and the drug was subjected to stress condition of acidic, basic, oxidation, reduction, UV light degradation, under same chromatographic condition. The stress samples were assayed on RP-HPLC system.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 46%
Lattice Boltzmann Simulation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.