A Comparative Study of Manual Vacuum Aspiration (MVA) and Electric Vacuum Aspiration (EVA) for the Surgical Management in Pregnancy Termination of Upto 10 Weeks Gestation

Introduction: Termination of pregnancy in the first trimester is one of the most commonly performed gynecological procedures worldwide. Both Manual Vacuum Aspiration (MVA) and Electric Vacuum Aspiration (EVA) are established methods for surgical management of early pregnancy termination. While both techniques are considered safe and effective, differences may exist in terms of efficacy, safety profile, complications, procedure time, and patient acceptability. Objectives: To compare the outcomes of Manual Vacuum Aspiration (MVA) and Electric Vacuum Aspiration (EVA) for pregnancy termination up to 10 weeks of gestation. Methods: This hospital-based prospective randomized comparative study was conducted over one year in the Department of Obstetrics & Gynecology at Chittaranjan Seva Sadan College. It included 200 women with firsttrimester abortion (≤10 weeks) who met the Government of India MTP criteria. Patients were randomized to undergo either Manual Vacuum Aspiration (MVA) or Electric Vacuum Aspiration (EVA), and data were collected on age, gravida, gestational age, locality, and socioeconomic status, cause of abortion, bleeding, complications, pain, and post-abortal contraceptive practices to compare outcomes between the two groups. Results: In this study of 200 patients, the MVA and EVA groups were comparable in age distribution, with the majority in the 21–30 years range (MVA: 71%, EVA: 64%; p=0.466) and similar gravida status (p=0.74), while gestational age showed a significant difference (p=0.02), with more patients at 5 weeks in the MVA group (5%) and more at 10 weeks in the EVA group (28%). Socioeconomic status also differed significantly (p=0.044), with a higher proportion of lower socioeconomic patients in the MVA group (77% vs 64%). Blood loss increased with gestational age, with MVA consistently lower than EVA (6 weeks: 23.5 ml vs 27.5 ml, p<0.001; 8 weeks: 28.46 ml vs 35.03 ml, p<0.001; 9 weeks: 33.4 ml vs 38.86 ml, p=0.01; 10 weeks: 36.29 ml vs 43.49 ml, p<0.001; 7 weeks difference not significant, 28.5 ml vs 32.3 ml, p=0.076). Hospital stay was shorter with MVA across all gestational ages (6–6.67 days) compared to EVA (13.2–15 days), with significant differences at 6, 8, 9, and 10 weeks. Grade I bleeding was more frequent in MVA (69% vs 13%), while higher grades occurred more in EVA (p<0.001). Pain was also lower with MVA (Grade I: 37% vs 0%; Grade IV: 7% vs 54%; p<0.001). Overall complications (p=0.215) and post-abortal contraceptive practices (p=0.345). Conclusion: Manual Vacuum Aspiration and Electric Vacuum Aspiration are both safe and effective techniques for surgical termination of pregnancy up to 10 weeks. MVA is particularly advantageous in resource-limited settings, while EVA may be more suitable in facilities with adequate infrastructure. The choice of method should be individualized based on patient preference, clinical setting, and resource availability.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-30
DOI
https://doi.org/10.5281/zenodo.17317876
Primary Topic
Reproductive Health and Contraception
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Study of Manual Vacuum Aspiration (MVA) and Electric Vacuum Aspiration (EVA) for the Surgical Management in Pregnancy Termination of Upto 10 Weeks Gestation

Zenodo (CERN European Organization for Nuclear Research)
Reproductive Health and Contraception
article

A Comparative Study of Manual Vacuum Aspiration (MVA) and Electric Vacuum Aspiration (EVA) for the Surgical Management in Pregnancy Termination of Upto 10 Weeks Gestation

article en

Abstract

Introduction: Termination of pregnancy in the first trimester is one of the most commonly performed gynecological procedures worldwide. Both Manual Vacuum Aspiration (MVA) and Electric Vacuum Aspiration (EVA) are established methods for surgical management of early pregnancy termination. While both techniques are considered safe and effective, differences may exist in terms of efficacy, safety profile, complications, procedure time, and patient acceptability. Objectives: To compare the outcomes of Manual Vacuum Aspiration (MVA) and Electric Vacuum Aspiration (EVA) for pregnancy termination up to 10 weeks of gestation. Methods: This hospital-based prospective randomized comparative study was conducted over one year in the Department of Obstetrics & Gynecology at Chittaranjan Seva Sadan College. It included 200 women with firsttrimester abortion (≤10 weeks) who met the Government of India MTP criteria. Patients were randomized to undergo either Manual Vacuum Aspiration (MVA) or Electric Vacuum Aspiration (EVA), and data were collected on age, gravida, gestational age, locality, and socioeconomic status, cause of abortion, bleeding, complications, pain, and post-abortal contraceptive practices to compare outcomes between the two groups. Results: In this study of 200 patients, the MVA and EVA groups were comparable in age distribution, with the majority in the 21–30 years range (MVA: 71%, EVA: 64%; p=0.466) and similar gravida status (p=0.74), while gestational age showed a significant difference (p=0.02), with more patients at 5 weeks in the MVA group (5%) and more at 10 weeks in the EVA group (28%). Socioeconomic status also differed significantly (p=0.044), with a higher proportion of lower socioeconomic patients in the MVA group (77% vs 64%). Blood loss increased with gestational age, with MVA consistently lower than EVA (6 weeks: 23.5 ml vs 27.5 ml, p<0.001; 8 weeks: 28.46 ml vs 35.03 ml, p<0.001; 9 weeks: 33.4 ml vs 38.86 ml, p=0.01; 10 weeks: 36.29 ml vs 43.49 ml, p<0.001; 7 weeks difference not significant, 28.5 ml vs 32.3 ml, p=0.076). Hospital stay was shorter with MVA across all gestational ages (6–6.67 days) compared to EVA (13.2–15 days), with significant differences at 6, 8, 9, and 10 weeks. Grade I bleeding was more frequent in MVA (69% vs 13%), while higher grades occurred more in EVA (p<0.001). Pain was also lower with MVA (Grade I: 37% vs 0%; Grade IV: 7% vs 54%; p<0.001). Overall complications (p=0.215) and post-abortal contraceptive practices (p=0.345). Conclusion: Manual Vacuum Aspiration and Electric Vacuum Aspiration are both safe and effective techniques for surgical termination of pregnancy up to 10 weeks. MVA is particularly advantageous in resource-limited settings, while EVA may be more suitable in facilities with adequate infrastructure. The choice of method should be individualized based on patient preference, clinical setting, and resource availability.

Zenodo (CERN European Organization for Nuclear Research)
Dinajpur Medical College (BD), Arthrex (United States) (US), Narayan Medical College and Hospital (IN)
Good health and well-being
Openalex Percentile: Top 35%
Reproductive Health and Contraception
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.