SIMULTANEOUS ESTIMATION OF METHOD DEVELOPMENT AND VALIDATION OF MONTELUKAST AND FEXOFENADINE BY USING REVERSE PHASE-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD

A simple, specific, precise and accurate Stability indicating RP-HPLC method for simultaneous estimation of Montelukast and Fexofenadine in its pure and pharmaceutical dosage form has been developed and validated as per ICH Guidelines. The separation was achieved by Phenomenex Gemini ODS C18 (4.6mm×250mm) 5µm column and Acetonitrile: Methanol: Water (55:25:20% v/v) used as mobile phase, at a flow rate of 1 ml/min. Detection was carried out at 229 nm. Retention time of Montelukast and Fexofenadine were found to be 2.157 min and 3.631 min respectively. The method has been validated for linearity, accuracy, precision, robustness, LOD and LOQ. Linearity observed for Montelukast 10 – 30μg/ml and for Fexofenadine 6 - 14μg/ml. Developed method was found to be accurate, precise and simple, specific for simultaneous estimation of Montelukast and Fexofenadine in pure form and their Combined Pharmaceutical Dosage Form. The precision results are not more than 2%. The proposed method was successfully applied for the simultaneous estimation of both the drugs in commercial combined dosage form.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-01
DOI
https://doi.org/10.5281/zenodo.17310462
Primary Topic
Forensic and Genetic Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SIMULTANEOUS ESTIMATION OF METHOD DEVELOPMENT AND VALIDATION OF MONTELUKAST AND FEXOFENADINE BY USING REVERSE PHASE-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD

Zenodo (CERN European Organization for Nuclear Research)
Forensic and Genetic Research
article

SIMULTANEOUS ESTIMATION OF METHOD DEVELOPMENT AND VALIDATION OF MONTELUKAST AND FEXOFENADINE BY USING REVERSE PHASE-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD

article en

Abstract

A simple, specific, precise and accurate Stability indicating RP-HPLC method for simultaneous estimation of Montelukast and Fexofenadine in its pure and pharmaceutical dosage form has been developed and validated as per ICH Guidelines. The separation was achieved by Phenomenex Gemini ODS C18 (4.6mm×250mm) 5µm column and Acetonitrile: Methanol: Water (55:25:20% v/v) used as mobile phase, at a flow rate of 1 ml/min. Detection was carried out at 229 nm. Retention time of Montelukast and Fexofenadine were found to be 2.157 min and 3.631 min respectively. The method has been validated for linearity, accuracy, precision, robustness, LOD and LOQ. Linearity observed for Montelukast 10 – 30μg/ml and for Fexofenadine 6 - 14μg/ml. Developed method was found to be accurate, precise and simple, specific for simultaneous estimation of Montelukast and Fexofenadine in pure form and their Combined Pharmaceutical Dosage Form. The precision results are not more than 2%. The proposed method was successfully applied for the simultaneous estimation of both the drugs in commercial combined dosage form.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 34%
Forensic and Genetic Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.