DEVELOPMENT AND VALIDATION OF RP-HPLC FOR ANALYTICAL ASSAY METHOD OF GENTAMICIN IN PHARMACEUTICAL OPHTHALMIC SOLUTION

A simple, precise, rapid and accurate RP- HPLC method was developed for the Estimation of gentamicin in pharmaceutical ophthalmic solution. An Phenomenex C18, 250 x 4.6mm dimension with 5µm particle size, the mobile phase, consisting of 0.1 % Trifluoroacetic acid and Methanol in the ratio of 70:30 v/v, prepare mixture of water and methanol used as a diluent for preparation of solution. The flow rate was 1.0 ml/min and 210 nm were used to monitor the effluents. The retention time was 4.2 for gentamicin. The detector response was linear in the concentration of 48-72 μg/mL for gentamicin. The respective linear regression equation being Y=239661x+180800 with corelation coefficient was 0.9997. The method was validated as per ICH guideline by determining its system suitability, specificity, linearity, accuracy, precision and Robustness. The results of the study demonstrated that the suggested RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of gentamicin in pharmaceutical ophthalmic solution.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-01
DOI
https://doi.org/10.5281/zenodo.17312252
Primary Topic
Chemical and Physical Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF RP-HPLC FOR ANALYTICAL ASSAY METHOD OF GENTAMICIN IN PHARMACEUTICAL OPHTHALMIC SOLUTION

Zenodo (CERN European Organization for Nuclear Research)
Chemical and Physical Studies
article

DEVELOPMENT AND VALIDATION OF RP-HPLC FOR ANALYTICAL ASSAY METHOD OF GENTAMICIN IN PHARMACEUTICAL OPHTHALMIC SOLUTION

article en

Abstract

A simple, precise, rapid and accurate RP- HPLC method was developed for the Estimation of gentamicin in pharmaceutical ophthalmic solution. An Phenomenex C18, 250 x 4.6mm dimension with 5µm particle size, the mobile phase, consisting of 0.1 % Trifluoroacetic acid and Methanol in the ratio of 70:30 v/v, prepare mixture of water and methanol used as a diluent for preparation of solution. The flow rate was 1.0 ml/min and 210 nm were used to monitor the effluents. The retention time was 4.2 for gentamicin. The detector response was linear in the concentration of 48-72 μg/mL for gentamicin. The respective linear regression equation being Y=239661x+180800 with corelation coefficient was 0.9997. The method was validated as per ICH guideline by determining its system suitability, specificity, linearity, accuracy, precision and Robustness. The results of the study demonstrated that the suggested RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of gentamicin in pharmaceutical ophthalmic solution.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 31%
Chemical and Physical Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.