On the impact of artifacts induced by mismatches between auto calibration signal and accelerated 3D GRE data at 11.7T

PurposeThe study aims at investigating B0 field inhomogeneity artifacts arising from remote locations in the FOV and encountered in accelerated 3D gradient-recalled echo (GRE) sequences at ultra-high field and at providing mitigation strategies. MethodsMeasurements were conducted at 11.7T using a head-shaped phantom and an accelerated 3D GRE sequence with either integrated or external auto-calibration signal (ACS) lines. Simulations were performed to reproduce the artifacts. The effects of varying GRAPPA reconstruction parameters (kernel size and regularization) were also examined. ResultsB0 field inhomogeneities located outside the B0 shimmed region of interest (i.e. the brain) were observed to return ripple-like artifacts within this region, particularly at long echo times. The simulation results support these findings, and the idea that the observed artifact originates from mismatch between ACS and accelerated data due to intra-voxel dephasing at different resolutions (ACS lines having an intrinsically lower resolution). The short echo time enabled by external (i.e., preacquired) ACS lines reduced artifacts compared to integrated ones. Varying GRAPPA kernel sizes and increasing the number of ACS lines can improve image quality yet without full compensation. ConclusionThis study highlights ripple-like artifacts amplified with field strength and arising from lack of coherence between the ACS and imaging (3D GRE) signal caused by B0 intra-voxel dephasing. To minimize these artifacts, care should be taken in order to preserve the relevant information in the ACS data to properly compute the GRAPPA kernels. Keywordsartifacts, auto-calibration signal, ultra-high field

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-09
DOI
https://doi.org/10.5281/zenodo.17304519
Primary Topic
Analytic Number Theory Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the impact of artifacts induced by mismatches between auto calibration signal and accelerated 3D GRE data at 11.7T

Zenodo (CERN European Organization for Nuclear Research)
Analytic Number Theory Research
article

On the impact of artifacts induced by mismatches between auto calibration signal and accelerated 3D GRE data at 11.7T

article en

Abstract

PurposeThe study aims at investigating B0 field inhomogeneity artifacts arising from remote locations in the FOV and encountered in accelerated 3D gradient-recalled echo (GRE) sequences at ultra-high field and at providing mitigation strategies. MethodsMeasurements were conducted at 11.7T using a head-shaped phantom and an accelerated 3D GRE sequence with either integrated or external auto-calibration signal (ACS) lines. Simulations were performed to reproduce the artifacts. The effects of varying GRAPPA reconstruction parameters (kernel size and regularization) were also examined. ResultsB0 field inhomogeneities located outside the B0 shimmed region of interest (i.e. the brain) were observed to return ripple-like artifacts within this region, particularly at long echo times. The simulation results support these findings, and the idea that the observed artifact originates from mismatch between ACS and accelerated data due to intra-voxel dephasing at different resolutions (ACS lines having an intrinsically lower resolution). The short echo time enabled by external (i.e., preacquired) ACS lines reduced artifacts compared to integrated ones. Varying GRAPPA kernel sizes and increasing the number of ACS lines can improve image quality yet without full compensation. ConclusionThis study highlights ripple-like artifacts amplified with field strength and arising from lack of coherence between the ACS and imaging (3D GRE) signal caused by B0 intra-voxel dephasing. To minimize these artifacts, care should be taken in order to preserve the relevant information in the ACS data to properly compute the GRAPPA kernels. Keywordsartifacts, auto-calibration signal, ultra-high field

Zenodo (CERN European Organization for Nuclear Research)
Centre National de la Recherche Scientifique (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Université Paris-Saclay (FR), German Center for Neurodegenerative Diseases (DE), Centre Inria de Saclay (FR), CEA Paris-Saclay (FR)
Openalex Percentile: Top 33%
Analytic Number Theory Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On the impact of artifacts induced by mismatches between auto calibration signal and accelerated 3D GRE data at 11.7T · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS