Development and Evaluation of a Miniature Scintillation Gamma Spectrometer for Environmental Radiation Monitoring

Developing a compact gamma spectrometer for radiation monitoring in critical zones, such as nuclear power plants and the Chernobyl Exclusion Zone, is vital for ensuring high sensitivity and accurate measurements amid geopolitical instability and military aggression. The aim of the study was to demonstrate the feasibility of a miniature scintillation spectrometer using a lutetium-yttrium oxyorthosilicate crystal (LYSO) and a silicon photomultiplier (SiPM) or multi-pixel photon counter (MPPC), and to compare it with an existing compact photomultiplier tube (PMT) R7400U assembly with a thallium-doped caesium iodide crystal (CsI(Tl)). The first stage involved preparing a prototype board for the R7400U PMT and analyzing its spectrometric characteristics. Next, an experimental setup using the LYSO crystal, SiPM photodiode, preamplifier electronics, and a spectrum analyzer was assembled, while gamma radiation interaction was modeled with GEANT4. Experimental measurements with a Cesium-137 (137Cs) source (661.7 keV) showed that the spectrometer could register and analyse gamma spectra with moderate resolution. The SiPM signal remained stable with optimal electronics and a 400 V DC-DC converter, providing low noise. Experimental data matched Monte Carlo simulations, and the SiPM's large pixel count ensured better response linearity at high light intensity. As a result, the design proved stable and effective for long-term measurements. The proposed approach demonstrated the possibility of such miniaturisation of spectrometric systems without significant degradation of performance. The study demonstrated the feasibility of a miniature scintillation spectrometer with LYSO and SiPM/MPPC, performing similarly to the PMT-based system. This compact design offers a viable solution for portable radiation monitoring in critical environments.

Institutions

Publication Details

Journal
Journal of Science and Mathematics Letters
Published
2025-09-21
DOI
https://doi.org/10.37134/jsml.vol13.2.7.2025
Primary Topic
Pregnancy-related medical research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Evaluation of a Miniature Scintillation Gamma Spectrometer for Environmental Radiation Monitoring

Journal of Science and Mathematics Letters
Pregnancy-related medical research
article

Development and Evaluation of a Miniature Scintillation Gamma Spectrometer for Environmental Radiation Monitoring

article en

Abstract

Developing a compact gamma spectrometer for radiation monitoring in critical zones, such as nuclear power plants and the Chernobyl Exclusion Zone, is vital for ensuring high sensitivity and accurate measurements amid geopolitical instability and military aggression. The aim of the study was to demonstrate the feasibility of a miniature scintillation spectrometer using a lutetium-yttrium oxyorthosilicate crystal (LYSO) and a silicon photomultiplier (SiPM) or multi-pixel photon counter (MPPC), and to compare it with an existing compact photomultiplier tube (PMT) R7400U assembly with a thallium-doped caesium iodide crystal (CsI(Tl)). The first stage involved preparing a prototype board for the R7400U PMT and analyzing its spectrometric characteristics. Next, an experimental setup using the LYSO crystal, SiPM photodiode, preamplifier electronics, and a spectrum analyzer was assembled, while gamma radiation interaction was modeled with GEANT4. Experimental measurements with a Cesium-137 (137Cs) source (661.7 keV) showed that the spectrometer could register and analyse gamma spectra with moderate resolution. The SiPM signal remained stable with optimal electronics and a 400 V DC-DC converter, providing low noise. Experimental data matched Monte Carlo simulations, and the SiPM's large pixel count ensured better response linearity at high light intensity. As a result, the design proved stable and effective for long-term measurements. The proposed approach demonstrated the possibility of such miniaturisation of spectrometric systems without significant degradation of performance. The study demonstrated the feasibility of a miniature scintillation spectrometer with LYSO and SiPM/MPPC, performing similarly to the PMT-based system. This compact design offers a viable solution for portable radiation monitoring in critical environments.

Journal of Science and Mathematics LettersVol. 13(2)
Taras Shevchenko National University of Kyiv (UA), Institute of Physics (UA)
Openalex Percentile: Top 36%
Pregnancy-related medical research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.