Assessing the fire safety practices in private schools of Quezon city

This study assessed the implementation of fire safety practices in selected private schools in Quezon City, Philippines. Using a descriptive survey design, 197 teaching and non-teaching personnel from seven schools were randomly sampled from a population of 392. A validated questionnaire measured implementation across fire safety practices, disaster management structures, and equipment readiness using a 4-point scale. Results show that core practices are generally fully implemented (overall ๐‘ฅฬ„ = 3.62), with highest ratings for easy-to-open doors and windows (๐‘ฅฬ„ = 3.94), timely repair of defective electrical components (๐‘ฅฬ„ = 3.86), the presence of fire escape plans, proper receptacles, and regular fire drills (all ๐‘ฅฬ„ = 3.76). Disaster Management Committees are also fully implemented (overall ๐‘ฅฬ„ = 3.66), informing personnel of plans and convening at least annually. In contrast, substantial equipment gaps persist: many schools lack fire blankets (73.60%), sand buckets (69.04%), sprinklers (60.91%), heat/smoke detectors (44.16%), and hoses/nozzles (43.65%). The findings indicate strong organizational and procedural compliance but insufficient physical protection systems, suggesting partial risk exposure despite adherence to RA 9514. Recommended actions include prioritizing active (alarms, detectors, sprinklers) and passive (egress, signage) protection upgrades; formal designation of fire safety officers; intensified electrical inspections; regular drills across the school year; and structural improvements (outward-swinging doors, dual exits in classrooms and laboratories, unobstructed egress). Strengthening equipment readiness will align practice with policy and enhance life safety and resilience in private schools.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-09-30
DOI
https://doi.org/10.5281/zenodo.17294784
Primary Topic
Sulfur Compounds in Biology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the fire safety practices in private schools of Quezon city

Zenodo (CERN European Organization for Nuclear Research)
Sulfur Compounds in Biology
article

Assessing the fire safety practices in private schools of Quezon city

article en

Abstract

This study assessed the implementation of fire safety practices in selected private schools in Quezon City, Philippines. Using a descriptive survey design, 197 teaching and non-teaching personnel from seven schools were randomly sampled from a population of 392. A validated questionnaire measured implementation across fire safety practices, disaster management structures, and equipment readiness using a 4-point scale. Results show that core practices are generally fully implemented (overall ๐‘ฅฬ„ = 3.62), with highest ratings for easy-to-open doors and windows (๐‘ฅฬ„ = 3.94), timely repair of defective electrical components (๐‘ฅฬ„ = 3.86), the presence of fire escape plans, proper receptacles, and regular fire drills (all ๐‘ฅฬ„ = 3.76). Disaster Management Committees are also fully implemented (overall ๐‘ฅฬ„ = 3.66), informing personnel of plans and convening at least annually. In contrast, substantial equipment gaps persist: many schools lack fire blankets (73.60%), sand buckets (69.04%), sprinklers (60.91%), heat/smoke detectors (44.16%), and hoses/nozzles (43.65%). The findings indicate strong organizational and procedural compliance but insufficient physical protection systems, suggesting partial risk exposure despite adherence to RA 9514. Recommended actions include prioritizing active (alarms, detectors, sprinklers) and passive (egress, signage) protection upgrades; formal designation of fire safety officers; intensified electrical inspections; regular drills across the school year; and structural improvements (outward-swinging doors, dual exits in classrooms and laboratories, unobstructed egress). Strengthening equipment readiness will align practice with policy and enhance life safety and resilience in private schools.

Zenodo (CERN European Organization for Nuclear Research)
Arcadis (Czechia) (CZ)
Climate action
Openalex Percentile: Top 45%
Sulfur Compounds in Biology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing the fire safety practices in private schools of Quezon city ยท Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS