Design of a low-frequency impedance measurement system applicable to LV grids in live conditions

The design of an impedance measurement system isdiscussed for application in low-voltage power grids in operation,addressing the presence of the grid voltage. A shunt injectionarrangement is preferred, relying then on the measurement ofthe port voltage and current. A Twin-T passive filter is designedto buffer the isolating injecting transformer, suppressing the50 Hz fundamental and avoiding excessive magnetizing currentand voltage the signal generator connected to the secondaryside. Before construction, the system has been simulated andparameters values optimized, showing good performance evenwith very large-power grids with impedance Zg of tens of mΩ.Zg estimate uncertainty is < 1 % at coverage factor k = 1.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-07-25
DOI
https://doi.org/10.5281/zenodo.17288690
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a low-frequency impedance measurement system applicable to LV grids in live conditions

Zenodo (CERN European Organization for Nuclear Research)
Cerebrospinal fluid and hydrocephalus
article

Design of a low-frequency impedance measurement system applicable to LV grids in live conditions

article en

Abstract

The design of an impedance measurement system isdiscussed for application in low-voltage power grids in operation,addressing the presence of the grid voltage. A shunt injectionarrangement is preferred, relying then on the measurement ofthe port voltage and current. A Twin-T passive filter is designedto buffer the isolating injecting transformer, suppressing the50 Hz fundamental and avoiding excessive magnetizing currentand voltage the signal generator connected to the secondaryside. Before construction, the system has been simulated andparameters values optimized, showing good performance evenwith very large-power grids with impedance Zg of tens of mΩ.Zg estimate uncertainty is < 1 % at coverage factor k = 1.

Zenodo (CERN European Organization for Nuclear Research)
University of Genoa (IT)
Affordable and clean energy
Openalex Percentile: Top 46%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.