UV-SPECTROPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BUDESONIDE IN BULK AND PHARMACEUTICAL DOSAGE FORM

A new, simple, accurate, and precise first-order derivative spectroscopic method was developed and validated to estimate Budesonide in bulk and Tablet dosage form. The stock solution was prepared by weighing 100 mg of standard Budesonide in a100 ml volumetric flask with Acetonitrile. The stock solution was made to produce 1000 µg/ml with Acetonitrile. Further dilutions were prepared as per the procedure. The drug solution showed the maximum absorbance at 241 nm. The linearity was found in the concentration range of 2-12µg/ml. The correlation coefficient was found to be 0.9982. The regression equation was found to be Y=0.0318x+0.0029. The method was validated for linearity, accuracy, precision, ruggedness, robustness, LOD and LOQ. The LOD and LOQ for estimation of Budesonide were found to be 0.3009 µg/ml and 0.9119 µg/ml respectively. Recovery of Budesonide was found to be in the range of 96-131%. The proposed method was successfully applied for the quantitative determination of Budesonide in bulk and Tablet dosage forms.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-08
DOI
https://doi.org/10.5281/zenodo.17296492
Primary Topic
Toxin Mechanisms and Immunotoxins
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

UV-SPECTROPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BUDESONIDE IN BULK AND PHARMACEUTICAL DOSAGE FORM

Zenodo (CERN European Organization for Nuclear Research)
Toxin Mechanisms and Immunotoxins
article

UV-SPECTROPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BUDESONIDE IN BULK AND PHARMACEUTICAL DOSAGE FORM

article en

Abstract

A new, simple, accurate, and precise first-order derivative spectroscopic method was developed and validated to estimate Budesonide in bulk and Tablet dosage form. The stock solution was prepared by weighing 100 mg of standard Budesonide in a100 ml volumetric flask with Acetonitrile. The stock solution was made to produce 1000 µg/ml with Acetonitrile. Further dilutions were prepared as per the procedure. The drug solution showed the maximum absorbance at 241 nm. The linearity was found in the concentration range of 2-12µg/ml. The correlation coefficient was found to be 0.9982. The regression equation was found to be Y=0.0318x+0.0029. The method was validated for linearity, accuracy, precision, ruggedness, robustness, LOD and LOQ. The LOD and LOQ for estimation of Budesonide were found to be 0.3009 µg/ml and 0.9119 µg/ml respectively. Recovery of Budesonide was found to be in the range of 96-131%. The proposed method was successfully applied for the quantitative determination of Budesonide in bulk and Tablet dosage forms.

Zenodo (CERN European Organization for Nuclear Research)
Industry, innovation and infrastructure
Openalex Percentile: Top 43%
Toxin Mechanisms and Immunotoxins
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

UV-SPECTROPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BUDESONIDE IN BULK AND PHARMACEUTICAL DOSAGE FORM · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS