Optimal time-step selection for accurate simulation results in the tumor growth simulation utility (TG-SU)

Accurate simulation of brain tumor growth is essential for predicting patient prognosis and evaluating treatment efficacy. The Tumor Growth Simulation Utility (TG-SU), based on the Reaction Diffusion Equation (RDE) and Finite Element (FE) method, provides a spatio-temporal framework to simulate glioma progression using segmented brain images. However, the choice of simulation time-step (dt) significantly impacts the accuracy and computational cost of the simulation. This study investigates the effect of varying time-step values on simulation error and computational rounds. Results show that while smaller time-steps improve accuracy, they increase simulation time. An equation is proposed to determine the optimal time-step for a given maximum acceptable error. This balance between speed and precision is crucial for practical neuro-oncology applications.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-30
DOI
https://doi.org/10.5281/zenodo.17283071
Primary Topic
Botulinum Toxin and Related Neurological Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal time-step selection for accurate simulation results in the tumor growth simulation utility (TG-SU)

Zenodo (CERN European Organization for Nuclear Research)
Botulinum Toxin and Related Neurological Disorders
article

Optimal time-step selection for accurate simulation results in the tumor growth simulation utility (TG-SU)

article en

Abstract

Accurate simulation of brain tumor growth is essential for predicting patient prognosis and evaluating treatment efficacy. The Tumor Growth Simulation Utility (TG-SU), based on the Reaction Diffusion Equation (RDE) and Finite Element (FE) method, provides a spatio-temporal framework to simulate glioma progression using segmented brain images. However, the choice of simulation time-step (dt) significantly impacts the accuracy and computational cost of the simulation. This study investigates the effect of varying time-step values on simulation error and computational rounds. Results show that while smaller time-steps improve accuracy, they increase simulation time. An equation is proposed to determine the optimal time-step for a given maximum acceptable error. This balance between speed and precision is crucial for practical neuro-oncology applications.

Zenodo (CERN European Organization for Nuclear Research)
Qatar University (QA)
Openalex Percentile: Top 38%
Botulinum Toxin and Related Neurological Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.