Development and Validation of a Material Response Model for Ablative Materials Undergoing Ground Testing

Material response (MR) modeling is critical to understanding and predicting the behavior of thermal protection systems (TPS) materials. It is also critical to the design of novel TPS materials. Developing an accurate MR model can be a complex, expensive, and time-consuming process. This paper details the development of a MR model of an Oxy-Acetylene Test Bed (OTB) system. 1dFIAT (One-Dimensional Fully Implicit Ablation and Thermal response program) was used to develop the MR model. Surface thermochemistry was generated using two different programs to create B-prime tables for the MR model. A model ablative material, Phenolic Impregnated Carbon Ablator (PICA), was evaluated at 5 different heat fluxes on the OTB. A sensitivity analysis of 1dFIAT was then performed to investigate the parameters that were contributing most to the error between the predicted and experimental values. A combination of material properties and environmental properties were measured and calculated to fulfill the required inputs to the MR model. The accuracy of the MR model was validated against the OTB experimental results for the PICA material. Learnings and challenges associated with the creation of the numerical model using this method and future applications of this approach are also discussed.

Publication Details

Journal
SAMPE JOURNAL
Published
2025-10-08
DOI
https://doi.org/10.33599/sj.v61no6.03
Primary Topic
Fungal and yeast genetics research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Material Response Model for Ablative Materials Undergoing Ground Testing

SAMPE JOURNAL
Fungal and yeast genetics research
article

Development and Validation of a Material Response Model for Ablative Materials Undergoing Ground Testing

article en

Abstract

Material response (MR) modeling is critical to understanding and predicting the behavior of thermal protection systems (TPS) materials. It is also critical to the design of novel TPS materials. Developing an accurate MR model can be a complex, expensive, and time-consuming process. This paper details the development of a MR model of an Oxy-Acetylene Test Bed (OTB) system. 1dFIAT (One-Dimensional Fully Implicit Ablation and Thermal response program) was used to develop the MR model. Surface thermochemistry was generated using two different programs to create B-prime tables for the MR model. A model ablative material, Phenolic Impregnated Carbon Ablator (PICA), was evaluated at 5 different heat fluxes on the OTB. A sensitivity analysis of 1dFIAT was then performed to investigate the parameters that were contributing most to the error between the predicted and experimental values. A combination of material properties and environmental properties were measured and calculated to fulfill the required inputs to the MR model. The accuracy of the MR model was validated against the OTB experimental results for the PICA material. Learnings and challenges associated with the creation of the numerical model using this method and future applications of this approach are also discussed.

SAMPE JOURNALVol. 61(6)
Life in Land
Openalex Percentile: Top 46%
Fungal and yeast genetics research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.