Simultaneous Measurement of Refractive Index and Temperature Based on Surface Plasmonic Resonance and Mode Coupling in a D-Shaped Hole-Assisted Dual-Core Fiber

A dual-parameter sensor based on a hybrid sensing mechanism of surface plasmon resonance (SPR) and mode resonance coupling in a D-shaped hole-assisted dual-core fiber (HADCF) is proposed and experimentally demonstrated. The D-shaped HADCF with Au film is used to excite the SPR for refractive index (RI) measurement, while the mode resonance coupling between the center core and suspended core of the HADCF is used for temperature measurement without RI crosstalk. The measured RI and temperature sensitivities of the sensor are 2907.31 nm/RIU and 2.86 nm/°C, respectively. Due to the advantages of compact size and temperature compensation capability, the proposed sensor has great potential for application in the field of biochemical analysis.

Institutions

Publication Details

Journal
Journal of Lightwave Technology
Published
2025-10-07
DOI
https://doi.org/10.1109/jlt.2025.3618607
Citations
1
Primary Topic
Anaerobic Digestion and Biogas Production
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Measurement of Refractive Index and Temperature Based on Surface Plasmonic Resonance and Mode Coupling in a D-Shaped Hole-Assisted Dual-Core Fiber

1 citations
Journal of Lightwave Technology
Anaerobic Digestion and Biogas Production
1.01
article

Simultaneous Measurement of Refractive Index and Temperature Based on Surface Plasmonic Resonance and Mode Coupling in a D-Shaped Hole-Assisted Dual-Core Fiber

article en
1 citations

Abstract

A dual-parameter sensor based on a hybrid sensing mechanism of surface plasmon resonance (SPR) and mode resonance coupling in a D-shaped hole-assisted dual-core fiber (HADCF) is proposed and experimentally demonstrated. The D-shaped HADCF with Au film is used to excite the SPR for refractive index (RI) measurement, while the mode resonance coupling between the center core and suspended core of the HADCF is used for temperature measurement without RI crosstalk. The measured RI and temperature sensitivities of the sensor are 2907.31 nm/RIU and 2.86 nm/°C, respectively. Due to the advantages of compact size and temperature compensation capability, the proposed sensor has great potential for application in the field of biochemical analysis.

Journal of Lightwave TechnologyVol. 43(24)
Northampton Community College (US), Harbin Engineering University (CN), University of Northampton (GB), Guilin University of Electronic Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 18%
Anaerobic Digestion and Biogas Production
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simultaneous Measurement of Refractive Index and Temperature Based on Surface Plasmonic Resonance and Mode Coupling in a D-Shaped Hole-Assisted Dual-Core Fiber · Journal of Lightwave Technology (2025) | TGRS Research Map | TGRS