Establishing of a National Diagnostic Reference Level for Radiation Dose in Digital Paediatric Pelvic X-Rays in Jordan: A Multicenter Retrospective Study

Malak AlHawadi, Mohammad Ayasrah Department of Allied Medical Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, 22110, JordanCorrespondence: Mohammad Ayasrah, Department of Allied Medical Sciences Faculty of Applied Medical Sciences, Jordan University of Science and Technology, P.O. Box 3030, Irbid, 22110, Jordan, Tel +96227201000-26939, Fax +96227201087, Email [email protected]: Paediatric pelvic X-rays are essential for diagnosing injuries and developmental abnormalities but pose radiation risks to sensitive children. Dose Reference Levels (DRLs) play a critical role in optimising radiographic procedures, ensuring both safety and high-quality imaging.Objective: This research aimed to establish a National Dose Reference Level (NDRL) for digital paediatric pelvic X-rays in Jordan to optimise radiation doses, improve diagnostic accuracy, and minimise risks.Methods: A Multicenter retrospective analysis was performed on paediatric Anterior-Posterior (AP) digital pelvic X-rays from various 12 Jordanian healthcare institutions. Parameters including Kilovoltage peak (kVp), milli Ampere second (mAs), and Focal to Skin Distance (FSD) were collected. Entrance Surface Dose (ESD) was indirectly calculated following international guidelines.Results: The study analysed 1,674 paediatric pelvic X-rays, finding a mean ESD of 0.69 milli-Gray (mGy). The 75th percentile ESD, or (DRL), was 0.612 mGy overall, with age-specific DRLs of 0.265 mGy (0 to < 1 year), 0.382 mGy (1 to < 5 years), 0.704 mGy (5 to < 10 years), and 0.995 mGy (10 to ≤ 15 years).Conclusion: The study revealed age-dependent variations and notable disparities in radiation doses among various healthcare institutions in Jordan. Establishing the NDRL of 0.612 mGy provides a benchmark for dose optimisation and aligns Jordan’s practices with international standards. The findings can guide national radiation protection policies and clinical guidelines, enhance paediatric imaging practices, and minimise unnecessary radiation exposure.Keywords: radiation safety, paediatric radiography, dose reference levels, DRLs, dose optimisation, medical imaging, Jordan

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-10-01
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing of a National Diagnostic Reference Level for Radiation Dose in Digital Paediatric Pelvic X-Rays in Jordan: A Multicenter Retrospective Study

SHILAP Revista de lepidopterología
Geochemistry and Geologic Mapping
article

Establishing of a National Diagnostic Reference Level for Radiation Dose in Digital Paediatric Pelvic X-Rays in Jordan: A Multicenter Retrospective Study

article en

Abstract

Malak AlHawadi, Mohammad Ayasrah Department of Allied Medical Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, 22110, JordanCorrespondence: Mohammad Ayasrah, Department of Allied Medical Sciences Faculty of Applied Medical Sciences, Jordan University of Science and Technology, P.O. Box 3030, Irbid, 22110, Jordan, Tel +96227201000-26939, Fax +96227201087, Email [email protected]: Paediatric pelvic X-rays are essential for diagnosing injuries and developmental abnormalities but pose radiation risks to sensitive children. Dose Reference Levels (DRLs) play a critical role in optimising radiographic procedures, ensuring both safety and high-quality imaging.Objective: This research aimed to establish a National Dose Reference Level (NDRL) for digital paediatric pelvic X-rays in Jordan to optimise radiation doses, improve diagnostic accuracy, and minimise risks.Methods: A Multicenter retrospective analysis was performed on paediatric Anterior-Posterior (AP) digital pelvic X-rays from various 12 Jordanian healthcare institutions. Parameters including Kilovoltage peak (kVp), milli Ampere second (mAs), and Focal to Skin Distance (FSD) were collected. Entrance Surface Dose (ESD) was indirectly calculated following international guidelines.Results: The study analysed 1,674 paediatric pelvic X-rays, finding a mean ESD of 0.69 milli-Gray (mGy). The 75th percentile ESD, or (DRL), was 0.612 mGy overall, with age-specific DRLs of 0.265 mGy (0 to < 1 year), 0.382 mGy (1 to < 5 years), 0.704 mGy (5 to < 10 years), and 0.995 mGy (10 to ≤ 15 years).Conclusion: The study revealed age-dependent variations and notable disparities in radiation doses among various healthcare institutions in Jordan. Establishing the NDRL of 0.612 mGy provides a benchmark for dose optimisation and aligns Jordan’s practices with international standards. The findings can guide national radiation protection policies and clinical guidelines, enhance paediatric imaging practices, and minimise unnecessary radiation exposure.Keywords: radiation safety, paediatric radiography, dose reference levels, DRLs, dose optimisation, medical imaging, Jordan

SHILAP Revista de lepidopterología
Allied Technology (United States) (US)
Partnerships for the goals
Openalex Percentile: Top 24%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Establishing of a National Diagnostic Reference Level for Radiation Dose in Digital Paediatric Pelvic X-Rays in Jordan: A Multicenter Retrospective Study · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS