Research to Optimize the Refrigerant Charge of the Natural Refrigerants R1270 and R290 in Heat-Pump Water Heaters and Their Performance

R1270 and R290 are alternative refrigerants with great potential. In this study, the influence of the refrigerant charge on the performance of the heat-pump water heater with R1270 and R290, the temperature distribution of the heat transfer fluids in the condenser, and the feasibility of replacing R22 with natural refrigerants were investigated. The results indicate that the refrigerant charge has a considerable influence on the cycle performance and the temperature distribution of the heat-transfer fluids in both systems. At the same optimal charge (0.90 kg), the R1270 and R290 systems achieved a maximum coefficient of performance (COP) of 4.443 and 4.317, respectively. At different refrigerant charges, two heat transfer pinch points and two maximum heat transfer temperature differences occurred in the condensers of both systems, and the locations of the first pinch point and the second maximum temperature difference point showed similar migrations with changes in refrigerant charge. Compared with the R22 system, both the R1270 and R290 systems, at optimal charge, achieved significantly better COP and discharge temperatures, exhibited relatively equivalent discharge pressures, and their heating capacities increased by 7.05% and decreased by 10.65%, respectively. Hence, R1270 can be preferred over R290 for replacing R22 in a heat-pump water heater.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-10-01
Primary Topic
Canadian Policy and Governance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research to Optimize the Refrigerant Charge of the Natural Refrigerants R1270 and R290 in Heat-Pump Water Heaters and Their Performance

SHILAP Revista de lepidopterología
Canadian Policy and Governance
article

Research to Optimize the Refrigerant Charge of the Natural Refrigerants R1270 and R290 in Heat-Pump Water Heaters and Their Performance

article en

Abstract

R1270 and R290 are alternative refrigerants with great potential. In this study, the influence of the refrigerant charge on the performance of the heat-pump water heater with R1270 and R290, the temperature distribution of the heat transfer fluids in the condenser, and the feasibility of replacing R22 with natural refrigerants were investigated. The results indicate that the refrigerant charge has a considerable influence on the cycle performance and the temperature distribution of the heat-transfer fluids in both systems. At the same optimal charge (0.90 kg), the R1270 and R290 systems achieved a maximum coefficient of performance (COP) of 4.443 and 4.317, respectively. At different refrigerant charges, two heat transfer pinch points and two maximum heat transfer temperature differences occurred in the condensers of both systems, and the locations of the first pinch point and the second maximum temperature difference point showed similar migrations with changes in refrigerant charge. Compared with the R22 system, both the R1270 and R290 systems, at optimal charge, achieved significantly better COP and discharge temperatures, exhibited relatively equivalent discharge pressures, and their heating capacities increased by 7.05% and decreased by 10.65%, respectively. Hence, R1270 can be preferred over R290 for replacing R22 in a heat-pump water heater.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 38%
Canadian Policy and Governance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.