XRISM/Xtend Transient Search (XTS) detected an X-ray flare from XRISM J1733-2440

XRISM/Xtend Transient Search (XTS) detected an X-ray flare from an X-ray source XRISM J1733-2440 on 2025-03-25 TT. The source position is determined to be (R.A., Dec.) = (263.262, -24.588), with a systematic error of ? 40 arcsec. A plausible counterpart is X-ray sources 1WGA J1733.0-2435, 4XMMs J173302.1-243510, or 2RXP J173302.0-243510. They are located within 15 arcsec from the position of XRISM J1733-2440. The flare reached its peak on 2025-03-25 at ? 15:19. The flare exponentially decayed in 8 × 103 sec. The flux at the flare peak is estimated as 6 × 10-13 erg s-1 cm-2 (0.4 – 10.0 keV). A systematic error of roughly 20% should be added to the statistical error. We estimated the systematic error for the source position from the separations between the detected sources with the corresponding counterparts in the same field of view.

Publication Details

Journal
Maryland Shared Open Access Repository (USMAI Consortium)
Published
2025-03-27
DOI
https://doi.org/10.13016/m2oyxx-3toy
Primary Topic
Membrane Separation and Gas Transport
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

XRISM/Xtend Transient Search (XTS) detected an X-ray flare from XRISM J1733-2440

Maryland Shared Open Access Repository (USMAI Consortium)
Membrane Separation and Gas Transport
article

XRISM/Xtend Transient Search (XTS) detected an X-ray flare from XRISM J1733-2440

article en

Abstract

XRISM/Xtend Transient Search (XTS) detected an X-ray flare from an X-ray source XRISM J1733-2440 on 2025-03-25 TT. The source position is determined to be (R.A., Dec.) = (263.262, -24.588), with a systematic error of ? 40 arcsec. A plausible counterpart is X-ray sources 1WGA J1733.0-2435, 4XMMs J173302.1-243510, or 2RXP J173302.0-243510. They are located within 15 arcsec from the position of XRISM J1733-2440. The flare reached its peak on 2025-03-25 at ? 15:19. The flare exponentially decayed in 8 × 103 sec. The flux at the flare peak is estimated as 6 × 10-13 erg s-1 cm-2 (0.4 – 10.0 keV). A systematic error of roughly 20% should be added to the statistical error. We estimated the systematic error for the source position from the separations between the detected sources with the corresponding counterparts in the same field of view.

Maryland Shared Open Access Repository (USMAI Consortium)
Openalex Percentile: Top 52%
Membrane Separation and Gas Transport
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.