Metrological characteristics research of a device for temperature normalization of the human organism state in elevated temperatures conditions

The article presents the results of a study on the metrological characteristics of an innovative device designed to normalize the thermal state of the human body under elevated ambient temperature conditions. The proposed device operates by activating natural thermoregulatory mechanisms via the vascular network of specific body areas, particularly the palms, enabling effective blood cooling through heat dissipation under conditions of reduced pressure. The structural scheme of the system is analyzed, and the main sources of instrumental errors are identified, including those associated with body temperature measurement, pressure in sealed chambers, coolant temperature, and blood flow monitoring. The total instrumental error of the device was calculated to be ±0.66 °C, with a relative error of 1.8%, which falls within acceptable limits for bioengineering systems intended for use in harsh industrial environments

Institutions

Publication Details

Journal
InterConf
Published
2025-06-20
DOI
https://doi.org/10.51582/interconf.19-20.06.2025.024
Primary Topic
Bacterial biofilms and quorum sensing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metrological characteristics research of a device for temperature normalization of the human organism state in elevated temperatures conditions

InterConf
Bacterial biofilms and quorum sensing
article

Metrological characteristics research of a device for temperature normalization of the human organism state in elevated temperatures conditions

article en

Abstract

The article presents the results of a study on the metrological characteristics of an innovative device designed to normalize the thermal state of the human body under elevated ambient temperature conditions. The proposed device operates by activating natural thermoregulatory mechanisms via the vascular network of specific body areas, particularly the palms, enabling effective blood cooling through heat dissipation under conditions of reduced pressure. The structural scheme of the system is analyzed, and the main sources of instrumental errors are identified, including those associated with body temperature measurement, pressure in sealed chambers, coolant temperature, and blood flow monitoring. The total instrumental error of the device was calculated to be ±0.66 °C, with a relative error of 1.8%, which falls within acceptable limits for bioengineering systems intended for use in harsh industrial environments

InterConf(58(252))
Ivano-Frankivsk National Technical University of Oil and Gas (UA)
Openalex Percentile: Top 47%
Bacterial biofilms and quorum sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Metrological characteristics research of a device for temperature normalization of the human organism state in elevated temperatures conditions · InterConf (2025) | TGRS Research Map | TGRS