Development of the timing system for the X-ray imaging and spectroscopy mission

We describe the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0 ms. All components of the timing system were designed and verified to be within the timing error budgets, which were assigned by component to meet the requirements. After the launch of XRISM, the timing capability of the ground-tuned timing system was verified using the millisecond pulsar PSR B1937+21 during the commissioning period, and the timing jitter of the bus and the ground component were found to be below 15 ?s compared with the NICER (Neutron star Interior Composition ExploreR) profile. During the performance verification and calibration period, simultaneous observations of the Crab pulsar by XRISM, NuSTAR (Nuclear Spectroscopic Telescope Array), and NICER were made to measure the absolute timing offset of the system, showing that the arrival time of the main pulse with XRISM was aligned with that of NICER and NuSTAR to within 200 ?s. In conclusion, the absolute timing accuracy of the bus and the ground component of the XRISM timing system meets the timing error budget of 500 ?s.

Publication Details

Journal
Maryland Shared Open Access Repository (USMAI Consortium)
Published
2025-04-07
DOI
https://doi.org/10.13016/m2eyru-rbgc
Primary Topic
Amyotrophic Lateral Sclerosis Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of the timing system for the X-ray imaging and spectroscopy mission

Maryland Shared Open Access Repository (USMAI Consortium)
Amyotrophic Lateral Sclerosis Research
article

Development of the timing system for the X-ray imaging and spectroscopy mission

article en

Abstract

We describe the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0 ms. All components of the timing system were designed and verified to be within the timing error budgets, which were assigned by component to meet the requirements. After the launch of XRISM, the timing capability of the ground-tuned timing system was verified using the millisecond pulsar PSR B1937+21 during the commissioning period, and the timing jitter of the bus and the ground component were found to be below 15 ?s compared with the NICER (Neutron star Interior Composition ExploreR) profile. During the performance verification and calibration period, simultaneous observations of the Crab pulsar by XRISM, NuSTAR (Nuclear Spectroscopic Telescope Array), and NICER were made to measure the absolute timing offset of the system, showing that the arrival time of the main pulse with XRISM was aligned with that of NICER and NuSTAR to within 200 ?s. In conclusion, the absolute timing accuracy of the bus and the ground component of the XRISM timing system meets the timing error budget of 500 ?s.

Maryland Shared Open Access Repository (USMAI Consortium)
Openalex Percentile: Top 38%
Amyotrophic Lateral Sclerosis Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.