Optimizing Radiation Exposure in Paediatric Trauma Imaging: Balancing Safety and Diagnostic Accuracy

Background: The challenge in paediatric trauma imaging is to minimize radiation exposure while maintaining diagnostic accuracy.Purpose: To evaluate the impact of a bundled radiation optimization protocol in a tertiary paediatric trauma center, focusing on radiation dose reduction and diagnostic outcomes.Methods: In this prospective audit, 420 trauma imaging encounters (210 pre-intervention, 210 post-intervention) were analyzed. The protocol included revised guidelines, increased use of ultrasound, low-dose CT, and clinician education. Primary outcomes were mean effective dose and imaging modality use; secondary outcomes included missed injuries and repeat imaging.Results: Mean effective dose per encounter declined from 5.84 ± 2.35 mSv (pre) to 2.34 ± 0.94 mSv (post, p<0.001). CT use dropped from 46% to 32%; ultrasound use rose from 19% to 33%. No significant difference was seen in missed injury rates (pre: 0.95%, post: 1.43%, p=0.65) or repeat imaging.Conclusion: A multidisciplinary radiation optimization protocol can significantly reduce radiation exposure in paediatric trauma imaging without compromising diagnostic accuracy.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-03
DOI
https://doi.org/10.5281/zenodo.17255178
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Radiation Exposure in Paediatric Trauma Imaging: Balancing Safety and Diagnostic Accuracy

Zenodo (CERN European Organization for Nuclear Research)
Radiation Dose and Imaging
article

Optimizing Radiation Exposure in Paediatric Trauma Imaging: Balancing Safety and Diagnostic Accuracy

article en

Abstract

Background: The challenge in paediatric trauma imaging is to minimize radiation exposure while maintaining diagnostic accuracy.Purpose: To evaluate the impact of a bundled radiation optimization protocol in a tertiary paediatric trauma center, focusing on radiation dose reduction and diagnostic outcomes.Methods: In this prospective audit, 420 trauma imaging encounters (210 pre-intervention, 210 post-intervention) were analyzed. The protocol included revised guidelines, increased use of ultrasound, low-dose CT, and clinician education. Primary outcomes were mean effective dose and imaging modality use; secondary outcomes included missed injuries and repeat imaging.Results: Mean effective dose per encounter declined from 5.84 ± 2.35 mSv (pre) to 2.34 ± 0.94 mSv (post, p<0.001). CT use dropped from 46% to 32%; ultrasound use rose from 19% to 33%. No significant difference was seen in missed injury rates (pre: 0.95%, post: 1.43%, p=0.65) or repeat imaging.Conclusion: A multidisciplinary radiation optimization protocol can significantly reduce radiation exposure in paediatric trauma imaging without compromising diagnostic accuracy.

Zenodo (CERN European Organization for Nuclear Research)
Quality Education
Openalex Percentile: Top 36%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimizing Radiation Exposure in Paediatric Trauma Imaging: Balancing Safety and Diagnostic Accuracy · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS