Optimizing Radiation Exposure in Paediatric Trauma Imaging: Balancing Safety and Diagnostic Accuracy

Background: The challenge in paediatric trauma imaging is to minimize radiation exposure while maintaining diagnostic accuracy.Purpose: To evaluate the impact of a bundled radiation optimization protocol in a tertiary paediatric trauma center, focusing on radiation dose reduction and diagnostic outcomes.Methods: In this prospective audit, 420 trauma imaging encounters (210 pre-intervention, 210 post-intervention) were analyzed. The protocol included revised guidelines, increased use of ultrasound, low-dose CT, and clinician education. Primary outcomes were mean effective dose and imaging modality use; secondary outcomes included missed injuries and repeat imaging.Results: Mean effective dose per encounter declined from 5.84 ± 2.35 mSv (pre) to 2.34 ± 0.94 mSv (post, p<0.001). CT use dropped from 46% to 32%; ultrasound use rose from 19% to 33%. No significant difference was seen in missed injury rates (pre: 0.95%, post: 1.43%, p=0.65) or repeat imaging.Conclusion: A multidisciplinary radiation optimization protocol can significantly reduce radiation exposure in paediatric trauma imaging without compromising diagnostic accuracy.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-03
DOI
https://doi.org/10.5281/zenodo.17255179
Primary Topic
Insect-Plant Interactions and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Radiation Exposure in Paediatric Trauma Imaging: Balancing Safety and Diagnostic Accuracy

Zenodo (CERN European Organization for Nuclear Research)
Insect-Plant Interactions and Control
article

Optimizing Radiation Exposure in Paediatric Trauma Imaging: Balancing Safety and Diagnostic Accuracy

article en

Abstract

Background: The challenge in paediatric trauma imaging is to minimize radiation exposure while maintaining diagnostic accuracy.Purpose: To evaluate the impact of a bundled radiation optimization protocol in a tertiary paediatric trauma center, focusing on radiation dose reduction and diagnostic outcomes.Methods: In this prospective audit, 420 trauma imaging encounters (210 pre-intervention, 210 post-intervention) were analyzed. The protocol included revised guidelines, increased use of ultrasound, low-dose CT, and clinician education. Primary outcomes were mean effective dose and imaging modality use; secondary outcomes included missed injuries and repeat imaging.Results: Mean effective dose per encounter declined from 5.84 ± 2.35 mSv (pre) to 2.34 ± 0.94 mSv (post, p<0.001). CT use dropped from 46% to 32%; ultrasound use rose from 19% to 33%. No significant difference was seen in missed injury rates (pre: 0.95%, post: 1.43%, p=0.65) or repeat imaging.Conclusion: A multidisciplinary radiation optimization protocol can significantly reduce radiation exposure in paediatric trauma imaging without compromising diagnostic accuracy.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 41%
Insect-Plant Interactions and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.