Design and Evaluation of CZT-based Micro-activity Dose Calibrator for TAT Application using Monte Carlo Simulation

A novel CZT-based micro-activity dose calibrator has been designed via Monte Carlo simulation (GATE) to accurately measure low-level activity 225Ac for targeted alpha therapy (TAT) application. Because even small overdoses in TAT can induce severe local toxicity, activities in the microcurie down to nanocurie regime are often required, and accurate activity measurement by dose calibrators is a priori to safe and effective treatment. Standard dose calibrators, or high-pressurized gas-filled ionization chambers, are not suitable in this range due to limited sensitivity and lack of energy discrimination. To address this, we designed a CZT-based micro-activity calibrator that (i) adopts a box-shaped well geometry to obtain higher solid-angle coverage and (ii) applies time-coincident pixel-level clustering to recover full-energy-peak net counts otherwise lost to multi-site Compton scattering. Using GATE, serial dilutions from 1.0 uCi down to 1e-6 uCi were simulated, activities were reconstructed from the 218 and 440 keV gamma peaks and performance was compared against a NaI(Tl) well counter, which serves as an alternative to standard dose calibrator. Across six orders of magnitude, the CZT-based micro-activity dose calibrator exhibited near-unity linearity (slope m=0.9934) with percent-level bias, whereas the NaI(Tl) counter showed systematic under-response under identical conditions. These results indicate that a CZT-based approach can provide accurate low-activity quantification for TAT, motivating forthcoming hardware validation.

Publication Details

Journal
ArXiv.org
Published
2025-09-30
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Evaluation of CZT-based Micro-activity Dose Calibrator for TAT Application using Monte Carlo Simulation

ArXiv.org
Facial Trauma and Fracture Management
article

Design and Evaluation of CZT-based Micro-activity Dose Calibrator for TAT Application using Monte Carlo Simulation

article en

Abstract

A novel CZT-based micro-activity dose calibrator has been designed via Monte Carlo simulation (GATE) to accurately measure low-level activity 225Ac for targeted alpha therapy (TAT) application. Because even small overdoses in TAT can induce severe local toxicity, activities in the microcurie down to nanocurie regime are often required, and accurate activity measurement by dose calibrators is a priori to safe and effective treatment. Standard dose calibrators, or high-pressurized gas-filled ionization chambers, are not suitable in this range due to limited sensitivity and lack of energy discrimination. To address this, we designed a CZT-based micro-activity calibrator that (i) adopts a box-shaped well geometry to obtain higher solid-angle coverage and (ii) applies time-coincident pixel-level clustering to recover full-energy-peak net counts otherwise lost to multi-site Compton scattering. Using GATE, serial dilutions from 1.0 uCi down to 1e-6 uCi were simulated, activities were reconstructed from the 218 and 440 keV gamma peaks and performance was compared against a NaI(Tl) well counter, which serves as an alternative to standard dose calibrator. Across six orders of magnitude, the CZT-based micro-activity dose calibrator exhibited near-unity linearity (slope m=0.9934) with percent-level bias, whereas the NaI(Tl) counter showed systematic under-response under identical conditions. These results indicate that a CZT-based approach can provide accurate low-activity quantification for TAT, motivating forthcoming hardware validation.

ArXiv.org
Ministry of Trade, Industry and Energy, Korea Institute of Energy Technology Evaluation and Planning
Peace, Justice and strong institutions
Openalex Percentile: Top 33%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.