Finite Element Analysis and In Vitro Assessment of Multirooted Custom Implants Manufactured by Additive and Subtractive Technologies

Objective: The aim of this study was to evaluate the accuracy of milled and 3D printed titanium and zirconia multi-rooted root analogue implants (RAIs) and compare their biomechanical behaviour to conventional threaded implants (TIs) experimentally and numerically through the creation of a validated finite element model. Materials and methods: A multi-rooted RAI was modelled based on tooth 47 segmented from cone-beam computed tomography (CBCT). Four RAI subgroups, 3D-printed titanium (PT), 3D-printed zirconia (PZ), milled titanium (MT), and milled zirconia (MZ), were fabricated, along with two TI subgroups (4.5 x 11 mm and 5.5 x 11 mm) as controls. Specimens were evaluated for precision and trueness using high-resolution scanning and 3D measurement software, with root mean square (RMS) deviations statistically analysed. Samples were embedded in artificial bone blocks and subjected to biomechanical testing using a specialised biomechanical test system to quantify micromotion. Additionally, a validated finite element model incorporating RAIs and TIs was developed, reproducing experimental boundary conditions. The model was assessed under immediate placement (touching contact) and osseointegrated conditions (glued contact). A 300 N load was applied axially and at 30° to evaluate equivalent stress, maximum principal stress, microstrain, and displacement. Results: PZ demonstrated the highest precision (RMS: 21±6 μm), while MZ had the highest trueness (RMS: 66±3 μm). MT exhibited the lowest trueness and the greatest deviation in the furcation area (612±64 μm). In vitro micromotion analysis showed no significant differences in the loading direction (Z-axis) between RAIs and TIs, whereas RAIs had higher total displacement compared to TIs (96.5 μm vs. 55.8 μm). Finite element analysis (FEA) showed that RAIs outperformed TIs, exhibiting lower stress, reduced microstrain (4,000 με vs. 13,000 με), and enhanced primary and secondary stability with lower micromotion. Conclusion: The manufacturing method significantly affected RAI accuracy, with PZ showing the highest precision and MZ the highest trueness. RAIs demonstrated promising biomechanical behaviour, though anatomical variations influenced predictability. FEA confirmed RAIs’ superior stress distribution and stability over TIs, highlighting their potential as a viable alternative for immediate implant placement.

Institutions

Publication Details

Journal
bonndoc (University of Bonn)
Published
2025-10-02
DOI
https://doi.org/10.48565/bonndoc-674
Primary Topic
Energy and Environment Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element Analysis and In Vitro Assessment of Multirooted Custom Implants Manufactured by Additive and Subtractive Technologies

bonndoc (University of Bonn)
Energy and Environment Impacts
article

Finite Element Analysis and In Vitro Assessment of Multirooted Custom Implants Manufactured by Additive and Subtractive Technologies

article en

Abstract

Objective: The aim of this study was to evaluate the accuracy of milled and 3D printed titanium and zirconia multi-rooted root analogue implants (RAIs) and compare their biomechanical behaviour to conventional threaded implants (TIs) experimentally and numerically through the creation of a validated finite element model. Materials and methods: A multi-rooted RAI was modelled based on tooth 47 segmented from cone-beam computed tomography (CBCT). Four RAI subgroups, 3D-printed titanium (PT), 3D-printed zirconia (PZ), milled titanium (MT), and milled zirconia (MZ), were fabricated, along with two TI subgroups (4.5 x 11 mm and 5.5 x 11 mm) as controls. Specimens were evaluated for precision and trueness using high-resolution scanning and 3D measurement software, with root mean square (RMS) deviations statistically analysed. Samples were embedded in artificial bone blocks and subjected to biomechanical testing using a specialised biomechanical test system to quantify micromotion. Additionally, a validated finite element model incorporating RAIs and TIs was developed, reproducing experimental boundary conditions. The model was assessed under immediate placement (touching contact) and osseointegrated conditions (glued contact). A 300 N load was applied axially and at 30° to evaluate equivalent stress, maximum principal stress, microstrain, and displacement. Results: PZ demonstrated the highest precision (RMS: 21±6 μm), while MZ had the highest trueness (RMS: 66±3 μm). MT exhibited the lowest trueness and the greatest deviation in the furcation area (612±64 μm). In vitro micromotion analysis showed no significant differences in the loading direction (Z-axis) between RAIs and TIs, whereas RAIs had higher total displacement compared to TIs (96.5 μm vs. 55.8 μm). Finite element analysis (FEA) showed that RAIs outperformed TIs, exhibiting lower stress, reduced microstrain (4,000 με vs. 13,000 με), and enhanced primary and secondary stability with lower micromotion. Conclusion: The manufacturing method significantly affected RAI accuracy, with PZ showing the highest precision and MZ the highest trueness. RAIs demonstrated promising biomechanical behaviour, though anatomical variations influenced predictability. FEA confirmed RAIs’ superior stress distribution and stability over TIs, highlighting their potential as a viable alternative for immediate implant placement.

bonndoc (University of Bonn)
University of Bonn (DE)
Openalex Percentile: Top 59%
Energy and Environment Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.