AI‑Enhanced Smartwatch AHI Estimation and AI‑Scored Polysomnography for Obstructive Sleep Apnea: Real‑World Validation
Donghyeok Kim,1 Jeong Yup Han,2 Hyunjun Jung,2 Da Yeun Song,1 Changhee Lee,1 Gwanghui Ryu,1 Sang Duk Hong,1 Hyo-Yeol Kim,1 Yong Gi Jung1,3 1Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea; 2Mobile eXperience, Samsung Electronics, Suwon, Gyeonggi, Republic of Korea; 3Department of Data Convergence and Future Medicine Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of KoreaCorrespondence: Yong Gi Jung, Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea, Tel +82-2-3410-3579, Fax +82-2-3410-3879, Email [email protected]: This study validated the accuracy of an artificialâintelligence (AI) smartwatch algorithm that directly estimates the apneaâhypopnea index (AHI) by comparing its performance with AI-scored Levelâ¯1 polysomnography (PSG) in Korean adults. The model was trained in SouthâAmerican cohorts, allowing interâethnic validation.Methods: A total of 90 adults underwent simultaneous Level 1 PSG and smartwatch recording. Fiftyâthree datasets with â¥â¯3â¯hours of valid watch data were analyzed. AHI values were obtained as follows: expertâscored PSG (pAHI), AIâscored PSG (aiAHI), and smartwatch output (eAHI). Agreement was assessed with Spearman correlation, intraclass correlation coefficients, and receiverâoperatingâcharacteristic curves.Results: eAHI correlated strongly with aiAHI (Ïâ¯=â¯0.88, ICCâ¯=â¯0.87) and pAHI (Ïâ¯=â¯0.85, ICCâ¯=â¯0.82). For detecting moderateâtoâsevere OSA (aiAHIâ¯â¥â¯15â¯events/h), the smartwatch algorithm yielded 92.3% sensitivity, 92.6% specificity, and 92.5% overall accuracy. BlandâAltman analysis revealed systematic underestimation of actual AHI by the smartwatch, particularly in mild OSA.Conclusion: This study demonstrates that the evaluated smartwatch-based AHI estimation algorithm shows high concordance with PSG-derived values, particularly for the detection and classification of moderate to severe OSA. However, it should be noted that this smartwatch algorithm tends to underestimate the AHI of OSA due to limitations in scoring unit and recording duration calculation. These findings support the clinical utility of wearable technology as a practical and scalable tool for early identification and longitudinal monitoring of OSA in real-world environments, while highlighting the need for further optimization to accurately detect mild cases.Keywords: sleep apnea syndromes, polysomnography, wearable electronic devices, artificial intelligence
Publication Details
- Journal
- Dove Medical Press (Taylor and Francis Group)
- Published
- 2025-09-22
- Primary Topic
- Rangeland and Wildlife Management
- Type
- article
- Field-Weighted Citation Impact
- 0.00