Measuring Uranium&Plutonium Content in MOX Fuel Based on Liquid Scintillator Detector

An analytical method for the determination of U and Pu contents in MOX fuels based on the liquid scintillator fast neutron coincidence counting method is presented. A Monte Carlo model was built based on the experimental setup to obtain the active and passive coincidence count rates of MOX fuel samples in the range of core block number 12-200. The U and Pu contents in the samples are determined by establishing the scale curves of the passive coincidence count rate versus the effective 240Pu mass,the scale curves of the active coincidence net count rate versus the effective 239Pu mass,and according to the differences in the contributions of U and Pu to the passive and active count rates. A method is given to simulate the acquisition of conversion factors for each isotope of U and Pu with respect to the effective 239Pu mass,and the feasibility of the method is verified with test samples.After scaling,the U and Pu contents of the unknown samples (number of cores >20,mass >30 g) were estimated,and the relative error of the samples with the number of cores >32 was less than 10%,which can be used as a reference for the analysis of the data in the quantitative measurement of uranium-plutonium in MOX fuels.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
DOI
https://doi.org/10.7538/tws.2025.youxian.001
Primary Topic
Genomics and Phylogenetic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring Uranium&Plutonium Content in MOX Fuel Based on Liquid Scintillator Detector

SHILAP Revista de lepidopterología
Genomics and Phylogenetic Studies
article

Measuring Uranium&Plutonium Content in MOX Fuel Based on Liquid Scintillator Detector

article en

Abstract

An analytical method for the determination of U and Pu contents in MOX fuels based on the liquid scintillator fast neutron coincidence counting method is presented. A Monte Carlo model was built based on the experimental setup to obtain the active and passive coincidence count rates of MOX fuel samples in the range of core block number 12-200. The U and Pu contents in the samples are determined by establishing the scale curves of the passive coincidence count rate versus the effective 240Pu mass,the scale curves of the active coincidence net count rate versus the effective 239Pu mass,and according to the differences in the contributions of U and Pu to the passive and active count rates. A method is given to simulate the acquisition of conversion factors for each isotope of U and Pu with respect to the effective 239Pu mass,and the feasibility of the method is verified with test samples.After scaling,the U and Pu contents of the unknown samples (number of cores >20,mass >30 g) were estimated,and the relative error of the samples with the number of cores >32 was less than 10%,which can be used as a reference for the analysis of the data in the quantitative measurement of uranium-plutonium in MOX fuels.

SHILAP Revista de lepidopterología
China Institute of Atomic Energy (CN)
Openalex Percentile: Top 48%
Genomics and Phylogenetic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measuring Uranium&Plutonium Content in MOX Fuel Based on Liquid Scintillator Detector · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS