Development of a Mechatronic End-Effector for Robot-Assisted Ultrasound Guided Tool Navigation in Local Destruction Procedures

The article is devoted to the development and analysis of the design of a mechatronic end-effector for a medical manipulator intended for ultrasound guided local destruction methods. A plane-parallel kinematic scheme of the end-effector, which has three controllable axis, was proposed, and it provides guidance and maintenance of the ablation tool insertion trajectory in the scanning plane of the ultrasonic transducer. A kinematic analysis of the design was conducted, including the forward and inverse kinematics problems, and a method for the coordinated motion planning of the end-effector and the medical manipulator was proposed. Design solutions are aimed at minimizing the positioning error of the system by shifting the center of mass and increasing its overall rigidity. The main provisions of the control algorithm are presented, which allows to keep the ablation tool in the visualization plane when the transducer position changes. The theoretical evaluation demonstrates the potential of the proposed end-effector to improve the accuracy and efficiency of minimally invasive interventions in clinical practice. In the future, it is planned to manufacture a prototype and integrate it into a medical manipulator for experimental evaluation.

Institutions

Publication Details

Published
2025-06-27
DOI
https://doi.org/10.1109/edm65517.2025.11096709
Primary Topic
Thermochemical Biomass Conversion Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Mechatronic End-Effector for Robot-Assisted Ultrasound Guided Tool Navigation in Local Destruction Procedures

Thermochemical Biomass Conversion Processes
article

Development of a Mechatronic End-Effector for Robot-Assisted Ultrasound Guided Tool Navigation in Local Destruction Procedures

article en

Abstract

The article is devoted to the development and analysis of the design of a mechatronic end-effector for a medical manipulator intended for ultrasound guided local destruction methods. A plane-parallel kinematic scheme of the end-effector, which has three controllable axis, was proposed, and it provides guidance and maintenance of the ablation tool insertion trajectory in the scanning plane of the ultrasonic transducer. A kinematic analysis of the design was conducted, including the forward and inverse kinematics problems, and a method for the coordinated motion planning of the end-effector and the medical manipulator was proposed. Design solutions are aimed at minimizing the positioning error of the system by shifting the center of mass and increasing its overall rigidity. The main provisions of the control algorithm are presented, which allows to keep the ablation tool in the visualization plane when the transducer position changes. The theoretical evaluation demonstrates the potential of the proposed end-effector to improve the accuracy and efficiency of minimally invasive interventions in clinical practice. In the future, it is planned to manufacture a prototype and integrate it into a medical manipulator for experimental evaluation.

Xenobe Research Institute (US)
Openalex Percentile: Top 51%
Thermochemical Biomass Conversion Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.