Impact of RF Coil Characteristics on 1.5T MRI RF-Induced Heating of Active Medical Implant Leads

The purpose of this study is to quantify the extent to which different coil characteristics of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{1. 5 T}$</tex> MRI scanners influence RF-induced lead heating of a patient with a Deep Brain Stimulator (DBS) implant. This evaluation was performed per the modeling approach of ISO/TS 10974:2018 [1] Clause 8 Tier 3, with a multitude of RF coils with different design parameters and lead heating predictions were compared. The results of this evaluation show that <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{R F}$</tex> coil length is the most impactful design parameter on implant heating, with minor influence attributable to coil diameter and topology. A secondary outcome was to determine if a reduced set of RF coils with specific characteristics can be used instead of a full extended set to reduce time.

Institutions

Publication Details

Published
2025-08-18
DOI
https://doi.org/10.1109/emcsipi52291.2025.11170172
Primary Topic
Innovative concrete reinforcement materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of RF Coil Characteristics on 1.5T MRI RF-Induced Heating of Active Medical Implant Leads

Innovative concrete reinforcement materials
article

Impact of RF Coil Characteristics on 1.5T MRI RF-Induced Heating of Active Medical Implant Leads

article en

Abstract

The purpose of this study is to quantify the extent to which different coil characteristics of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{1. 5 T}$</tex> MRI scanners influence RF-induced lead heating of a patient with a Deep Brain Stimulator (DBS) implant. This evaluation was performed per the modeling approach of ISO/TS 10974:2018 [1] Clause 8 Tier 3, with a multitude of RF coils with different design parameters and lead heating predictions were compared. The results of this evaluation show that <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{R F}$</tex> coil length is the most impactful design parameter on implant heating, with minor influence attributable to coil diameter and topology. A secondary outcome was to determine if a reduced set of RF coils with specific characteristics can be used instead of a full extended set to reduce time.

Boston Scientific (United States) (US)
Openalex Percentile: Top 49%
Innovative concrete reinforcement materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.