High-Frequency Modal Analysis via Low-Speed DIC: Mitigation of Harmonic Peaks in the FRF

Digital Image Correlation (DIC) is a technique that has seen a growth in popularity for use in modal analysis, due to its full-field, non-contact measurement capabilities. Recent developments in the field are focused on achieving reliable data acquisition at rates of up to 1 kHz using costeffective configurations. This study explores the potential of using a low-speed stereo camera configuration to assess the vibrational response of a structure. A previously implemented technique, which reconstructs down-sampled data collected by time-shifting the trigger of a stereo-camera system [1], resulted in the introduction of harmonic peaks in the frequency response function (FRF) of the test specimen. To identify the underlying causes, a detailed analysis was performed using an exclusionbased approach. In contrast to the prior method, a novel technique was developed to collect down-sampled data by temporally displacing the force signal while maintaining a constant camera acquisition frequency. Preliminary results indicate the need for further investigation, and post-processing algorithms were evaluated to mitigate harmonic peaks, of which the Cepstral filter demonstrated successful attenuation.

Institutions

Publication Details

Published
2025-06-18
DOI
https://doi.org/10.1109/metroaerospace64938.2025.11114418
Primary Topic
Agriculture Sustainability and Environmental Impact
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Frequency Modal Analysis via Low-Speed DIC: Mitigation of Harmonic Peaks in the FRF

Agriculture Sustainability and Environmental Impact
article

High-Frequency Modal Analysis via Low-Speed DIC: Mitigation of Harmonic Peaks in the FRF

article en

Abstract

Digital Image Correlation (DIC) is a technique that has seen a growth in popularity for use in modal analysis, due to its full-field, non-contact measurement capabilities. Recent developments in the field are focused on achieving reliable data acquisition at rates of up to 1 kHz using costeffective configurations. This study explores the potential of using a low-speed stereo camera configuration to assess the vibrational response of a structure. A previously implemented technique, which reconstructs down-sampled data collected by time-shifting the trigger of a stereo-camera system [1], resulted in the introduction of harmonic peaks in the frequency response function (FRF) of the test specimen. To identify the underlying causes, a detailed analysis was performed using an exclusionbased approach. In contrast to the prior method, a novel technique was developed to collect down-sampled data by temporally displacing the force signal while maintaining a constant camera acquisition frequency. Preliminary results indicate the need for further investigation, and post-processing algorithms were evaluated to mitigate harmonic peaks, of which the Cepstral filter demonstrated successful attenuation.

Siemens (Belgium) (BE), University of Naples Federico II (IT)
Climate action
Openalex Percentile: Top 41%
Agriculture Sustainability and Environmental Impact
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.