Multi-band graphene-nested rings terahertz wave absorber with air gap for sensitive healthcare biosensing applications

A highly sensitive multi-band terahertz wave absorber is proposed, featuring a three-layer structure with a central air gap for blood sample placement, sandwiched by stacked graphene-Kapton layers and backed by a fully reflecting metallic layer. The absorber is modeled using an equivalent impedance circuit and validated by full-wave numerical simulations. The device exhibits seven distinct absorption peaks across the 1 to 9.5 THz frequency range, with absorption levels exceeding 80% for each peak. Sensitivity analysis reveals robust absorption performance with minimal variation against geometrical parameter changes, while demonstrating high sensitivity to refractive index changes within the air gap. Specifically, the absorption spectrum shifts significantly for refractive index variations as small as 0.01, which is critical for non-invasive biosensing applications. These results underscore the absorber’s potential as an accurate, wearable, and reliable building block for healthcare monitoring systems.

Institutions

Publication Details

Journal
Results in Optics
Published
2025-10-01
DOI
https://doi.org/10.1016/j.rio.2025.100911
Citations
2
Primary Topic
Human Mobility and Location-Based Analysis
Type
article
Field-Weighted Citation Impact
4.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-band graphene-nested rings terahertz wave absorber with air gap for sensitive healthcare biosensing applications

2 citations
Results in Optics
Human Mobility and Location-Based Analysis
4.35
article

Multi-band graphene-nested rings terahertz wave absorber with air gap for sensitive healthcare biosensing applications

article en
2 citations

Abstract

A highly sensitive multi-band terahertz wave absorber is proposed, featuring a three-layer structure with a central air gap for blood sample placement, sandwiched by stacked graphene-Kapton layers and backed by a fully reflecting metallic layer. The absorber is modeled using an equivalent impedance circuit and validated by full-wave numerical simulations. The device exhibits seven distinct absorption peaks across the 1 to 9.5 THz frequency range, with absorption levels exceeding 80% for each peak. Sensitivity analysis reveals robust absorption performance with minimal variation against geometrical parameter changes, while demonstrating high sensitivity to refractive index changes within the air gap. Specifically, the absorption spectrum shifts significantly for refractive index variations as small as 0.01, which is critical for non-invasive biosensing applications. These results underscore the absorber’s potential as an accurate, wearable, and reliable building block for healthcare monitoring systems.

Results in OpticsVol. 21
Islamic Azad University, Tehran (IR), Islamic Azad University Sari Branch (IR), Islamic Azad University, Nowshahr Branch (IR), University of Science and Technology of Mazandaran (IR)
Openalex Percentile: Top 6%
Human Mobility and Location-Based Analysis
4.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multi-band graphene-nested rings terahertz wave absorber with air gap for sensitive healthcare biosensing applications · Results in Optics (2025) | TGRS Research Map | TGRS