Analysis of the Parameters of Antiscatter X-Ray Grids for Dental Microscopy

To study the internal structure of solids, X-rays are often used, which penetrate to great depths. However, the radiation is scattered by the object and reduces the effectiveness of the X-ray microscopy method of solids. An analysis of the attenuation of scattered radiation by antiscatter X-ray grids made of aluminum, nickel and gold is carried out. During the calculation process, such grid parameters as cell size, grid thickness, grid filling factor with metal, and X-ray quantum energy were varied. It is shown that when using them, a spatial resolution of several micrometers can be achieved for a relatively thick object (up to 1 cm in size in the direction of propagation of the X-ray beam) in beams of both monochromatic and non-monochromatic radiation within the photon energy of 40 keV. The spatial resolution is strongly dependent on the degree of metal filling in the mesh and the thickness of the mesh.

Institutions

Publication Details

Published
2025-06-27
DOI
https://doi.org/10.1109/edm65517.2025.11096754
Primary Topic
Agriculture, Water, and Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Parameters of Antiscatter X-Ray Grids for Dental Microscopy

Agriculture, Water, and Health
article

Analysis of the Parameters of Antiscatter X-Ray Grids for Dental Microscopy

article en

Abstract

To study the internal structure of solids, X-rays are often used, which penetrate to great depths. However, the radiation is scattered by the object and reduces the effectiveness of the X-ray microscopy method of solids. An analysis of the attenuation of scattered radiation by antiscatter X-ray grids made of aluminum, nickel and gold is carried out. During the calculation process, such grid parameters as cell size, grid thickness, grid filling factor with metal, and X-ray quantum energy were varied. It is shown that when using them, a spatial resolution of several micrometers can be achieved for a relatively thick object (up to 1 cm in size in the direction of propagation of the X-ray beam) in beams of both monochromatic and non-monochromatic radiation within the photon energy of 40 keV. The spatial resolution is strongly dependent on the degree of metal filling in the mesh and the thickness of the mesh.

Institute of Solid State Chemistry and Mechanochemistry (RU), Budker Institute of Nuclear Physics (RU)
Openalex Percentile: Top 48%
Agriculture, Water, and Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.