Minimum Voltage Injection for Sensorless Control of IPMSMs using Three-Shunt Current Sensors

This paper presents a switching-frequency voltage injection method for low-speed sensorless control using three-shunt current sensing inverters (TCSIs). Due to the current sensing limitations of TCSIs, the injection frequency is limited to half of the switching frequency using conventional injection-based sensorless methods – PWM modification is required to achieve switching-frequency voltage injection. Therefore, this paper proposes a switching-frequency voltage injection method that requires no PWM modification. The rotor position is estimated by utilizing current derivatives measured from a single active vector. To accurately measure current derivatives, a minimum duration of the active vector is required. To ensure this condition, the minimum voltage injection (MVI) method is introduced, which guarantees sufficient duration of the V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</inf>, V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>, or V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</inf> vector. The effectiveness of the proposed method is experimentally validated, demonstrating rotor position estimation errors within 0.1 rad.

Institutions

Publication Details

Published
2025-08-15
DOI
https://doi.org/10.1109/sled63792.2025.11154739
Primary Topic
Reconstructive Facial Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimum Voltage Injection for Sensorless Control of IPMSMs using Three-Shunt Current Sensors

Reconstructive Facial Surgery Techniques
article

Minimum Voltage Injection for Sensorless Control of IPMSMs using Three-Shunt Current Sensors

article en

Abstract

This paper presents a switching-frequency voltage injection method for low-speed sensorless control using three-shunt current sensing inverters (TCSIs). Due to the current sensing limitations of TCSIs, the injection frequency is limited to half of the switching frequency using conventional injection-based sensorless methods – PWM modification is required to achieve switching-frequency voltage injection. Therefore, this paper proposes a switching-frequency voltage injection method that requires no PWM modification. The rotor position is estimated by utilizing current derivatives measured from a single active vector. To accurately measure current derivatives, a minimum duration of the active vector is required. To ensure this condition, the minimum voltage injection (MVI) method is introduced, which guarantees sufficient duration of the V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</inf>, V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>, or V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</inf> vector. The effectiveness of the proposed method is experimentally validated, demonstrating rotor position estimation errors within 0.1 rad.

Seoul National University (KR)
Affordable and clean energy
Openalex Percentile: Top 33%
Reconstructive Facial Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Minimum Voltage Injection for Sensorless Control of IPMSMs using Three-Shunt Current Sensors · (2025) | TGRS Research Map | TGRS