The Solution for Grid-Connected Inverters in Order to Comply with Grid-Code: Integrating SHEPWM and 30° Phase-Shifted Two-Channel Inverter Topology

This paper presents an approach to optimizing control algorithms for a grid-connected inverter. The scientific novelty of the solution is expressed in a hybrid approach to inverter control, combining a two-channel inverter circuit <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(6 \mathrm{n} \pm 1$</tex> harmonic mitigation) with the optimal synchronous modulation method, Selective Harmonic Elimination Pulse Width Modulation, which eliminates <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$12 n \pm 1$</tex> harmonics. This combination ensures more stable and reliable power unit operation under various grid conditions. A detailed harmonic spectrum analysis at the Point of Common Coupling was conducted. Each modulation pattern was evaluated under different operating conditions, including connection to high-, medium-, and low-power grids, operation on a matched load, and operation for auxiliary power consumption. The proposed optimization aims to enhance operational efficiency, minimize power fluctuations, and improve the system's response to grid disturbances. The study includes a comprehensive theoretical analysis, the development of mathematical models, and the implementation of optimized synchronous modulation patterns in MATLAB/Simulink. Experimental validation demonstrates a significant reduction in total harmonic distortion and an overall improvement in power quality compliance. The experimental results confirm a significant reduction in Total Harmonic Distortion and an overall improvement in power quality compliance. These findings suggest practical applications in modern power systems, where power quality and efficiency are crucial.

Institutions

Publication Details

Published
2025-06-27
DOI
https://doi.org/10.1109/edm65517.2025.11096775
Primary Topic
Malaria Research and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Solution for Grid-Connected Inverters in Order to Comply with Grid-Code: Integrating SHEPWM and 30° Phase-Shifted Two-Channel Inverter Topology

Malaria Research and Control
article

The Solution for Grid-Connected Inverters in Order to Comply with Grid-Code: Integrating SHEPWM and 30° Phase-Shifted Two-Channel Inverter Topology

article en

Abstract

This paper presents an approach to optimizing control algorithms for a grid-connected inverter. The scientific novelty of the solution is expressed in a hybrid approach to inverter control, combining a two-channel inverter circuit <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(6 \mathrm{n} \pm 1$</tex> harmonic mitigation) with the optimal synchronous modulation method, Selective Harmonic Elimination Pulse Width Modulation, which eliminates <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$12 n \pm 1$</tex> harmonics. This combination ensures more stable and reliable power unit operation under various grid conditions. A detailed harmonic spectrum analysis at the Point of Common Coupling was conducted. Each modulation pattern was evaluated under different operating conditions, including connection to high-, medium-, and low-power grids, operation on a matched load, and operation for auxiliary power consumption. The proposed optimization aims to enhance operational efficiency, minimize power fluctuations, and improve the system's response to grid disturbances. The study includes a comprehensive theoretical analysis, the development of mathematical models, and the implementation of optimized synchronous modulation patterns in MATLAB/Simulink. Experimental validation demonstrates a significant reduction in total harmonic distortion and an overall improvement in power quality compliance. The experimental results confirm a significant reduction in Total Harmonic Distortion and an overall improvement in power quality compliance. These findings suggest practical applications in modern power systems, where power quality and efficiency are crucial.

Ural Federal University (RU), NPO Energomash (Russia) (RU)
Affordable and clean energy
Openalex Percentile: Top 37%
Malaria Research and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Solution for Grid-Connected Inverters in Order to Comply with Grid-Code: Integrating SHEPWM and 30° Phase-Shifted Two-Channel Inverter Topology · (2025) | TGRS Research Map | TGRS