Features of General Primary Frequency Control in Isolated Power Systems

The article explores the features of general primary frequency control in isolated power systems characterized by low inertia, limited power reserves, and a high share of hydropower generation. The study employs a digital mathematical model replicating the Norilsk-Taimyr Energy Company power system to identify critical challenges in general primary frequency control: persistent frequency oscillations arising from mismatches between static and astatic regulators, conventional control algorithms that inadequately adapt to isolated systems with high hydropower integration, and delayed responses to abrupt load shifts. Validation against data from a real Norilsk-Taimyr Energy Company power system incident demonstrates the model's ability to simulate transient dynamics, including frequency oscillations during power deficits. The practical significance of this study lies in developing a tool for optimizing general primary frequency control in isolated power systems in Russia (e.g., Arctic and Far East regions). This tool aims to reduce emergency shutdowns, minimize equipment wear and tear, and facilitate the integration of renewable energy sources. Future research directions include the development of adaptive algorithms with constraints on power ramp rates and improved coordination of diverse generation sources.

Institutions

Publication Details

Published
2025-06-27
DOI
https://doi.org/10.1109/edm65517.2025.11096899
Citations
1
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
2.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Features of General Primary Frequency Control in Isolated Power Systems

1 citations
Geochemistry and Geologic Mapping
2.48
article

Features of General Primary Frequency Control in Isolated Power Systems

article en
1 citations

Abstract

The article explores the features of general primary frequency control in isolated power systems characterized by low inertia, limited power reserves, and a high share of hydropower generation. The study employs a digital mathematical model replicating the Norilsk-Taimyr Energy Company power system to identify critical challenges in general primary frequency control: persistent frequency oscillations arising from mismatches between static and astatic regulators, conventional control algorithms that inadequately adapt to isolated systems with high hydropower integration, and delayed responses to abrupt load shifts. Validation against data from a real Norilsk-Taimyr Energy Company power system incident demonstrates the model's ability to simulate transient dynamics, including frequency oscillations during power deficits. The practical significance of this study lies in developing a tool for optimizing general primary frequency control in isolated power systems in Russia (e.g., Arctic and Far East regions). This tool aims to reduce emergency shutdowns, minimize equipment wear and tear, and facilitate the integration of renewable energy sources. Future research directions include the development of adaptive algorithms with constraints on power ramp rates and improved coordination of diverse generation sources.

Novosibirsk State Technical University (RU)
Affordable and clean energy
Openalex Percentile: Top 6%
Geochemistry and Geologic Mapping
2.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.