The 3D Printing Method for Preparing 131I Thyroid Body Source

This research investigates the utilization of 3D printing technology and the phase transfer method to fabricate photosensitive resin containing the radionuclide 131I,aiming to simulate the neck-thyroid source model for the efficiency calibration of detectors. Through optimizing the type,dosage,mixing time of the phase transfer agent,as well as the addition amount of 131I,a well-uniform 131I photosensitive resin was successfully prepared. By means of 3D printing technology,the thyroid source model was fabricated and a comparative measurement was conducted with the IAEA (International Atomic Energy Agency)/ANSI (American National Standards Institute) neck phantom. The experimental results indicate that the detection efficiency of the thyroid source model prepared using 131I photosensitive resin is in line with that of the IAEA/ANSI neck phantom,proving the feasibility of 3D printing technology and phase transfer method for preparing photosensitive resin thyroid body source and offering a novel approach for the preparation of other complex heterogeneous source models.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-06-01
DOI
https://doi.org/10.7538/tws.2025.youxian.009
Primary Topic
Seed and Plant Biochemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The 3D Printing Method for Preparing 131I Thyroid Body Source

SHILAP Revista de lepidopterología
Seed and Plant Biochemistry
article

The 3D Printing Method for Preparing 131I Thyroid Body Source

article en

Abstract

This research investigates the utilization of 3D printing technology and the phase transfer method to fabricate photosensitive resin containing the radionuclide 131I,aiming to simulate the neck-thyroid source model for the efficiency calibration of detectors. Through optimizing the type,dosage,mixing time of the phase transfer agent,as well as the addition amount of 131I,a well-uniform 131I photosensitive resin was successfully prepared. By means of 3D printing technology,the thyroid source model was fabricated and a comparative measurement was conducted with the IAEA (International Atomic Energy Agency)/ANSI (American National Standards Institute) neck phantom. The experimental results indicate that the detection efficiency of the thyroid source model prepared using 131I photosensitive resin is in line with that of the IAEA/ANSI neck phantom,proving the feasibility of 3D printing technology and phase transfer method for preparing photosensitive resin thyroid body source and offering a novel approach for the preparation of other complex heterogeneous source models.

SHILAP Revista de lepidopterología
China Institute of Atomic Energy (CN)
Affordable and clean energy
Openalex Percentile: Top 44%
Seed and Plant Biochemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.