Gramian Angular Field–Gramian Adversial Network–ResNet34: High-Accuracy Fault Diagnosis for Transformer Windings with Limited Samples

Transformers are critical equipment in power transmission and distribution systems, and the condition of their windings significantly impacts their reliable operation. Therefore, the fault diagnosis of transformer windings is of great importance. Addressing the challenge of limited fault samples in traditional diagnostic methods, this study proposes a small-sample fault diagnosis method for transformer windings. This method combines data augmentation using the Gramian angular field (GAF) and generative adversarial networks (GAN) with a deep residual network (ResNet). First, by establishing a transformer winding fault simulation experiment platform, frequency response curves for three types of faults—axial displacement, bulging and warping, and cake-to-cake short circuits—and different fault regions were obtained using the frequency response analysis method (FRA). Second, a frequency response curve image conversion technique based on the Gramian angular field was proposed, converting the frequency response curves into Gramian angular summation field (GASF) and Gramian angular difference field (GADF) images using the Gramian angular field. Next, we introduce several improved GANs to augment the frequency response data and evaluate the quality of the generated samples. We compared and analysed the diagnostic accuracy of ResNet34 networks trained using different GAF–GAN combination datasets for winding fault types, and we proposed a transformer winding small-sample fault diagnosis method based on GAF-GAN-ResNet34, which can achieve a fault identification accuracy rate of 96.88% even when using only 28 real samples. Finally, we applied the proposed fault diagnosis method to on-site transformers to verify its classification performance under small-sample conditions. The results show that, even with insufficient fault samples, the proposed method can achieve high diagnostic accuracy.

Institutions

Publication Details

Journal
Energies
Published
2025-08-14
DOI
https://doi.org/10.3390/en18164329
Citations
1
Primary Topic
Posttraumatic Stress Disorder Research
Type
article
Field-Weighted Citation Impact
2.31
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gramian Angular Field–Gramian Adversial Network–ResNet34: High-Accuracy Fault Diagnosis for Transformer Windings with Limited Samples

1 citations
Energies
Posttraumatic Stress Disorder Research
2.31
article

Gramian Angular Field–Gramian Adversial Network–ResNet34: High-Accuracy Fault Diagnosis for Transformer Windings with Limited Samples

article en
1 citations

Abstract

Transformers are critical equipment in power transmission and distribution systems, and the condition of their windings significantly impacts their reliable operation. Therefore, the fault diagnosis of transformer windings is of great importance. Addressing the challenge of limited fault samples in traditional diagnostic methods, this study proposes a small-sample fault diagnosis method for transformer windings. This method combines data augmentation using the Gramian angular field (GAF) and generative adversarial networks (GAN) with a deep residual network (ResNet). First, by establishing a transformer winding fault simulation experiment platform, frequency response curves for three types of faults—axial displacement, bulging and warping, and cake-to-cake short circuits—and different fault regions were obtained using the frequency response analysis method (FRA). Second, a frequency response curve image conversion technique based on the Gramian angular field was proposed, converting the frequency response curves into Gramian angular summation field (GASF) and Gramian angular difference field (GADF) images using the Gramian angular field. Next, we introduce several improved GANs to augment the frequency response data and evaluate the quality of the generated samples. We compared and analysed the diagnostic accuracy of ResNet34 networks trained using different GAF–GAN combination datasets for winding fault types, and we proposed a transformer winding small-sample fault diagnosis method based on GAF-GAN-ResNet34, which can achieve a fault identification accuracy rate of 96.88% even when using only 28 real samples. Finally, we applied the proposed fault diagnosis method to on-site transformers to verify its classification performance under small-sample conditions. The results show that, even with insufficient fault samples, the proposed method can achieve high diagnostic accuracy.

EnergiesVol. 18(16)
Southwest Jiaotong University (CN)
Openalex Percentile: Top 9%
Posttraumatic Stress Disorder Research
2.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Gramian Angular Field–Gramian Adversial Network–ResNet34: High-Accuracy Fault Diagnosis for Transformer Windings with Limited Samples · Energies (2025) | TGRS Research Map | TGRS