Exploration of Monte Carlo Simulation from a Case Study of Particle Transport in the Gamma Knife Perfexion™ Machine

Introduction: Gamma Knife Perfexion™ delivers 192 Cobalt-60 sources to the focal point (isocenter), and the patient is fixed using a stereotactic frame. In conformal techniques, the width of the penumbra resulting in an out-of-field dose of normal tissue adjacent to the tumor must be accurately determined. The purpose of this study was to calculate the penumbra widths of a single beam and 192 beams for different collimator sizes of the Gamma Knife Perfexion™ using the BEAMNRC/DOSXYZNRC Monte Carlo simulation code and compare the results with EBT3 film dosimetry data. Material and Methods: To investigate the physical penumbra width (80-20%), the single beam and 192 beam profiles were obtained using the DOSXYZNRC code and EBT3 films located at the isocenter point in a spherical solid water phantom with a diameter of 160 mm. Results: The results showed that the Gamma Passing Rate (GPR) value for all collimator sizes has a value above 97%. The single-beam penumbra widths obtained from simulation data for 4, 8, and 16 mm collimator sizes along the X-axis were 0.75, 0.77, and 0.87 mm, respectively. The data for 192 beams obtained from the simulation were 2.60, 4.80, and 8.70 mm along the X-axis. Conclusion: The differences between measured and simulated penumbra widths are in an acceptable range. However, for more precise measurement in the penumbra region with a high dose gradient, a Monte Carlo simulation is recommended.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.22038/ijmp.2025.82592.2457
Primary Topic
Business, Education, Mathematics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploration of Monte Carlo Simulation from a Case Study of Particle Transport in the Gamma Knife Perfexion™ Machine

SHILAP Revista de lepidopterología
Business, Education, Mathematics Research
article

Exploration of Monte Carlo Simulation from a Case Study of Particle Transport in the Gamma Knife Perfexion™ Machine

article en

Abstract

Introduction: Gamma Knife Perfexion™ delivers 192 Cobalt-60 sources to the focal point (isocenter), and the patient is fixed using a stereotactic frame. In conformal techniques, the width of the penumbra resulting in an out-of-field dose of normal tissue adjacent to the tumor must be accurately determined. The purpose of this study was to calculate the penumbra widths of a single beam and 192 beams for different collimator sizes of the Gamma Knife Perfexion™ using the BEAMNRC/DOSXYZNRC Monte Carlo simulation code and compare the results with EBT3 film dosimetry data. Material and Methods: To investigate the physical penumbra width (80-20%), the single beam and 192 beam profiles were obtained using the DOSXYZNRC code and EBT3 films located at the isocenter point in a spherical solid water phantom with a diameter of 160 mm. Results: The results showed that the Gamma Passing Rate (GPR) value for all collimator sizes has a value above 97%. The single-beam penumbra widths obtained from simulation data for 4, 8, and 16 mm collimator sizes along the X-axis were 0.75, 0.77, and 0.87 mm, respectively. The data for 192 beams obtained from the simulation were 2.60, 4.80, and 8.70 mm along the X-axis. Conclusion: The differences between measured and simulated penumbra widths are in an acceptable range. However, for more precise measurement in the penumbra region with a high dose gradient, a Monte Carlo simulation is recommended.

SHILAP Revista de lepidopterología
Universitas Prima Nusantara Bukittinggi (ID), Universitas Muhammadiyah Sumatera Barat (ID), Siloam Eye Hospital (KR), Andalas University (ID)
Openalex Percentile: Top 35%
Business, Education, Mathematics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exploration of Monte Carlo Simulation from a Case Study of Particle Transport in the Gamma Knife Perfexion™ Machine · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS