VNA-Based in-Band Spectral Purity Assessment for MM-Wave Frequency Extenders

This work presents a method for measuring the inband spectral content of mm-wave extenders using a vector network analyzer. In active device characterization, controlling the output power of the extenders through their low-frequency input signal power requires high spectral purity to avoid affecting the measurement results. To assess the frequency harmonic content, the proposed approach combines vector power calibration with a harmonic scanning technique, where only the local oscillator of the extender under test is varied across a predefined frequency grid. Since the measurement relies solely on the vector network analyzer, this method enables high-speed evaluation of in-band harmonic contributions with a high dynamic range. The paper first compares the proposed approach with broadband PM5 measurements, demonstrating a very good agreement with a maximum deviation of 0.8 dB. Subsequently, a complete characterization of the Virginia Diodes WR6.5 extender <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(110-170 \text{GHz})$</tex> is presented. The results indicate an in-band harmonic contribution of less than 1.4 dB up to an output power of −60 dB.

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/arftg65332.2025.11168129
Primary Topic
Food Security and Health in Diverse Populations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VNA-Based in-Band Spectral Purity Assessment for MM-Wave Frequency Extenders

Food Security and Health in Diverse Populations
article

VNA-Based in-Band Spectral Purity Assessment for MM-Wave Frequency Extenders

article en

Abstract

This work presents a method for measuring the inband spectral content of mm-wave extenders using a vector network analyzer. In active device characterization, controlling the output power of the extenders through their low-frequency input signal power requires high spectral purity to avoid affecting the measurement results. To assess the frequency harmonic content, the proposed approach combines vector power calibration with a harmonic scanning technique, where only the local oscillator of the extender under test is varied across a predefined frequency grid. Since the measurement relies solely on the vector network analyzer, this method enables high-speed evaluation of in-band harmonic contributions with a high dynamic range. The paper first compares the proposed approach with broadband PM5 measurements, demonstrating a very good agreement with a maximum deviation of 0.8 dB. Subsequently, a complete characterization of the Virginia Diodes WR6.5 extender <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(110-170 \text{GHz})$</tex> is presented. The results indicate an in-band harmonic contribution of less than 1.4 dB up to an output power of −60 dB.

Cross-Linked Enzyme Aggregates Technologies (Netherlands) (NL), Delft University of Technology (NL)
Openalex Percentile: Top 33%
Food Security and Health in Diverse Populations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.