Fast Ion Extraction Control System for ESIS

The pulsed electron-string ion source KRION-6T is the primary device for producing highly charged heavy ions in the injection complex of Nuclotron-based Ion Collider Facility at the Laboratory of High Energy Physics of Joint Institute for Nuclear Research. During the fourth phase of commissioning the Nuclotron-based Ion Collider Facility complex in 2022–2023, <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">${}^{124}\mathbf{Xe}^{28+}$</tex> ions <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\mathbf{Z}/\mathbf{A}=1/4.4)$</tex> obtained from the KRION-6T source were accelerated to an energy of 3.9 GeV/nucleon. The ion extraction system, previously developed and used in this acceleration session, set a minimum ion extraction time from the ion trap of the KRION-6T source at <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\tau \geq 12$</tex> us. However, to ensure more efficient injection of the ion beam into the Booster, the ion extraction time from the source needed to be reduced to <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{\tau}\boldsymbol{\sim} 4$</tex> us (the design injection time of the beam). The presented work describes a new electronic control system for the ion trap, enabling the fast extraction of ions from the KRION-6T source, achieving an extraction time for <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">${}^{124}\mathbf{Xe}^{28+}$</tex> ions of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{\tau}\boldsymbol{\sim} 4$</tex> μs,

Institutions

Publication Details

Published
2025-06-27
DOI
https://doi.org/10.1109/edm65517.2025.11096888
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast Ion Extraction Control System for ESIS

Diverse Scientific and Economic Studies
article

Fast Ion Extraction Control System for ESIS

article en

Abstract

The pulsed electron-string ion source KRION-6T is the primary device for producing highly charged heavy ions in the injection complex of Nuclotron-based Ion Collider Facility at the Laboratory of High Energy Physics of Joint Institute for Nuclear Research. During the fourth phase of commissioning the Nuclotron-based Ion Collider Facility complex in 2022–2023, <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">${}^{124}\mathbf{Xe}^{28+}$</tex> ions <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\mathbf{Z}/\mathbf{A}=1/4.4)$</tex> obtained from the KRION-6T source were accelerated to an energy of 3.9 GeV/nucleon. The ion extraction system, previously developed and used in this acceleration session, set a minimum ion extraction time from the ion trap of the KRION-6T source at <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\tau \geq 12$</tex> us. However, to ensure more efficient injection of the ion beam into the Booster, the ion extraction time from the source needed to be reduced to <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{\tau}\boldsymbol{\sim} 4$</tex> us (the design injection time of the beam). The presented work describes a new electronic control system for the ion trap, enabling the fast extraction of ions from the KRION-6T source, achieving an extraction time for <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">${}^{124}\mathbf{Xe}^{28+}$</tex> ions of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{\tau}\boldsymbol{\sim} 4$</tex> μs,

Joint Institute for Nuclear Research (RU)
Openalex Percentile: Top 34%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.