EarFusion: Quality-Aware Fusion of In-Ear Audio and Photoplethysmography for Heart Rate Monitoring

Wearable devices are increasingly adopted for continuous heart rate (HR) monitoring, yet existing solutions remain constrained by modality-specific vulnerabilities. Photoplethysmography (PPG), the most widely used technique, suffers from motion artifacts, skin-sensor variability, and ambient light, whereas in-ear audio sensing, an emerging alternative, is robust to many motion disturbances but easily corrupted by ambient noise and self-speech. These complementary failure modes motivate an integrated approach that can dynamically adapt to signal reliability. This paper introduces EarFusion, the first framework that integrates in-ear audio and PPG for HR estimation through quality-aware fusion. We design modality-specific Signal Quality Indices (SQIs) and incorporate them into a fusion algorithm that allocates trust across streams in real time. Experiments on the OmniBuds platform across diverse activities with synchronized ECG ground truth validate both the effectiveness and feasibility of the approach. EarFusion reduces HR estimation error compared to single-modality baselines, consistently achieves lower variance than either modality alone, and further benefits from SQI-driven integration relative to using a single quality measure.

Institutions

Publication Details

Published
2025-09-22
DOI
https://doi.org/10.1145/3737901.3768366
Primary Topic
Canadian Policy and Governance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EarFusion: Quality-Aware Fusion of In-Ear Audio and Photoplethysmography for Heart Rate Monitoring

Canadian Policy and Governance
article

EarFusion: Quality-Aware Fusion of In-Ear Audio and Photoplethysmography for Heart Rate Monitoring

article en

Abstract

Wearable devices are increasingly adopted for continuous heart rate (HR) monitoring, yet existing solutions remain constrained by modality-specific vulnerabilities. Photoplethysmography (PPG), the most widely used technique, suffers from motion artifacts, skin-sensor variability, and ambient light, whereas in-ear audio sensing, an emerging alternative, is robust to many motion disturbances but easily corrupted by ambient noise and self-speech. These complementary failure modes motivate an integrated approach that can dynamically adapt to signal reliability. This paper introduces EarFusion, the first framework that integrates in-ear audio and PPG for HR estimation through quality-aware fusion. We design modality-specific Signal Quality Indices (SQIs) and incorporate them into a fusion algorithm that allocates trust across streams in real time. Experiments on the OmniBuds platform across diverse activities with synchronized ECG ground truth validate both the effectiveness and feasibility of the approach. EarFusion reduces HR estimation error compared to single-modality baselines, consistently achieves lower variance than either modality alone, and further benefits from SQI-driven integration relative to using a single quality measure.

Nokia (United Kingdom) (GB)
Openalex Percentile: Top 39%
Canadian Policy and Governance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.