A high-stability optical clock based on a continuously ground-state cooled Al$^+$ ion without compromising its accuracy

Single ion optical clocks have shown systematic frequency uncertainties below $10^{-18}$, but typically require more than one week of averaging to achieve a corresponding statistical uncertainty. This time can be reduced with longer probe times, but comes at the cost of a higher time-dilation shift due to motional heating of the ions in the trap. We show that sympathetic ground-state cooling using electromagnetically-induced transparency (EIT) of an \Al clock ion via a co-trapped \Ca ion during clock interrogation suppresses the heating of the ions. \Al can be kept close to the motional ground state, independent from the chosen interrogation time, at a relative time dilation shift of $(-1.69\pm0.20)\times10^{-18}$. The \Ca cooling light introduces an additional light shift on the \Al clock transition of $(-9.27\pm 1.03)\times10^{-18}$. We project that the uncertainty of this light shift can be further reduced by nearly an order of magnitude. This sympathetic cooling enables seconds of interrogation time with $10^{-19}$ motional and cooling laser-induced uncertainties for \Al and can be employed in other ion clocks as well.

Publication Details

Journal
ArXiv.org
Published
2025-09-26
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A high-stability optical clock based on a continuously ground-state cooled Al$^+$ ion without compromising its accuracy

ArXiv.org
Corrosion Behavior and Inhibition
article

A high-stability optical clock based on a continuously ground-state cooled Al$^+$ ion without compromising its accuracy

article en

Abstract

Single ion optical clocks have shown systematic frequency uncertainties below $10^{-18}$, but typically require more than one week of averaging to achieve a corresponding statistical uncertainty. This time can be reduced with longer probe times, but comes at the cost of a higher time-dilation shift due to motional heating of the ions in the trap. We show that sympathetic ground-state cooling using electromagnetically-induced transparency (EIT) of an \Al clock ion via a co-trapped \Ca ion during clock interrogation suppresses the heating of the ions. \Al can be kept close to the motional ground state, independent from the chosen interrogation time, at a relative time dilation shift of $(-1.69\pm0.20)\times10^{-18}$. The \Ca cooling light introduces an additional light shift on the \Al clock transition of $(-9.27\pm 1.03)\times10^{-18}$. We project that the uncertainty of this light shift can be further reduced by nearly an order of magnitude. This sympathetic cooling enables seconds of interrogation time with $10^{-19}$ motional and cooling laser-induced uncertainties for \Al and can be employed in other ion clocks as well.

ArXiv.org
Openalex Percentile: Top 58%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A high-stability optical clock based on a continuously ground-state cooled Al$^+$ ion without compromising its accuracy · ArXiv.org (2025) | TGRS Research Map | TGRS